Page 135
Speed Level Seres - Servce & Parts Manual
January 2019
Secton 9 - Troubleshootng - 3084ES Models
EZ-Cal Setup
Refer to “EZ-Cal Scan Tool” on page 127.
Operation
ID
Personality
Factory Setting
Explanation
6A
CHANGE
DEFAULTS
6A-1
Customer
5=xx84ES
Choose basic model and power source
6A-2
Model Select
3 = 3084ES ANSI
4 = 3084ES CE
Choose model and certification
6D
TILT SETUPS
6B-1
Calibrate Level?
Y = ENTER
N = ESC
Follow instructions in Section 7 - Level Sensor Calibration
WARNING! Refer to Tilt Sensor Calibration instructions before attempting calibration
6B-2
Tilt Shutdown
0 = Never
Function shutdown tilted when platform stowed
6B-3
Elev Tilt Shutdown
1 = Lift & Drive
Function shutdown tilted when platform elevated
6B-4
Axle Tilt
3.0 deg
Oscillating axle maximum interlock angle
6C
HEIGHT SETUP
6C-1
Elevation @
15%
% of maximum height when system goes into elevated
mode
6C-2
Calibrate Height
Start Calibration
See Section 7 for calibration of Height Sensor
6C-3
Min Lift
1.0 sec
Calibration setting - do not change
6C-4
Samples
0.30 sec
Calibration setting - do not change
6C-5
Tilt Correction
3=Y+
Calibration setting - do not change
6C-6
Slow Down
10%
Calibration setting - do not change
6D
LOAD SETUPS
(EUROPEAN
OPTION ONLY)
6D-1
Calibrate Load
Start Calibration
See Section 7 for calibration of CE Overload System
6D-2
Faulty Load
-100%
Calibration setting - do not change
6D-3
Dynamic Scale
110%
Calibration setting - do not change
6E
INTERLOCKS
6E-1
Trigger Only
10.0 sec
Time that the enable bar can be held without operation
before timeout
6E-2
Trigger Wait
0.0 sec
Delay before function after enable bar is actuated
6E-3
Function hold
0.2 sec
Function enabled after operator release
6E-4
Throttle Delay
0.0 sec
Delay before throttle enabled (not used)
6E-5
Starter Delay
10.0 sec
Starter over-crank feature; time starter is off (not used)