Page 63
Speed Level Seres - Servce & Parts Manual
January 2019
Secton 6 - Electrcal System
The Platform Overload Sensing System is now calibrated.
CE Height Calibration
For this procedure it is
not
necessary to place any load in the platform.
Drive machine to a flat, level surface where it can reach full elevation.
Turn selector switch to Base controls.
Plug EZ-Cal into connector P9 on GP400 Control Module.
Display reads HELP: PRESS ENTER
Press right arrow to ACCESS LEVEL 3. Press Enter.
Display reads CODE 0000
Press Up and Right Arrow to enter code 2222. Press Enter.
Display reads ACCESS LEVEL 2.
On later models, the display may continue to read “ACCESS LEVEL 3”. Repeat step b. and
enter code 1775.
Press Right Arrow to SETUPS. Press Enter.
Display reads CHANGE DEFAULTS
Press Right Arrow to HEIGHT SETUPS. Press Enter.
Display reads CALIBRATE HEIGHT
Press Enter.
Display reads PLATFORM DOWN?
Verify that platform is fully lowered. Press Enter.
Display reads PLEASE LIFT.
Hold lower controls switch in the up position until machine is fully elevated, then release switch.
Display reads PLEASE LOWER.
Hold switch in down position until platform is in the fully lowered position. Release switch.
Display reads FINISHED.
1.
2.
3.
•
4.
•
5.
•
•
6.
•
7.
•
8.
•
9.
•
10.
•
11.
•