Page 69
Speed Level Seres - Servce & Parts Manual
January 2019
Secton 6 - Electrcal System
Information Messages
During calibration the following messages will be displayed. They are informational prompts only and
do not indicate a failure.
BUILDING TABLES
This message indicates that the STATIC measurements are being used to build calibration data
- the process should take no more than 5s.
CALDATE:
This message is prompting for the date to be entered; it is stored to identify when the machine
was calibrated.
The last calibrate date can be viewed in DIAGNOSTICS / LOG.
Press LEFT & RIGHT to select the flashing digits.
Press UP & DOWN to change the flashing digits.
Press ENTER when the entry is complete.
IMPORTANT:
The date 00/00/00 is not allowed!
FINISHED
This message confirms that calibration is complete and successful.
GO DOWN MORE!
This message occurs if the DOWN switch is released during either STATIC lowering phase,
when more measurements are needed (before the platform is fully lowered).
GO UP MORE!
This message occurs if the UP switch is released during either STATIC lifting phase, when more
measurements are needed (before the platform is fully raised).
LIFT EMPTY
This message is displayed during the STATIC empty phase while the platform is being raised to
the next measurement height.
LIFT LOADED
This message is displayed during the STATIC loaded phase while the platform is being raised to
the next measurement height.
LIFTING
This message is displayed during the DYNAMIC phase while the platform is being raised.
LOWER EMPTY
This message is displayed during the STATIC empty phase while the platform is being lowered
to the next measurement height.
LOWER LOADED
This message is displayed during the STATIC loaded phase while the platform is being lowered
to the next measurement height.
LOWERING
This message is displayed during the DYNAMIC phase while the platform is being lowered.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•