MSI-3750 Digital Weight Indicator
◆
User Guide
Page 63
M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
≈
UV
F3
GREATER
∆
ENTER
SETUP
➇
2
DEF
2_
➇
0
SPACE
20_
➇
0
SPACE
200_
➈
ENTER
DEADZONE
10
5
MNO
5_
10
0
SPACE
50_
11
ENTER
VALUE
12
UV
F3
DELAY
select "GREATER. For a "less than" set
point, push the
UP
key to select
"LESSTHAN". In this example we’ll
program a overload warning set at
≥
200lb
so we will leave the sense at “GREATER”.
LESSTHAN and GREATER are shown
here for clarity. There is no need to use the
UP
key to scroll to LESSTHAN if
GREATER is what you want.
7)
Push
ENTER
to accept GREATER than as
the set point sensing mode. The weight
entry screen now appears.
8)
Input the desired set point Value with the
numeric keys.
Note: Set point Values are limited to Capacity
+5% unless the WGT MODE is “TOTAL”. Dual
Input 3750s are limited to the sum of the
capacity of Input A plus the capacity of Input B
+5%.
9)
Push
ENTER
to store your set point value.
10) You are now in the “DEAD ZONE VALUE
MENU”.This step is optional. Skip to step
11 if a Dead Zone value is not needed
(Dead Zone value of 0). Use the numeric
keys to input the weight range desired for
the Dead Zone.
In this example we desire a dead zone of 50
lb. The example set point will turn on at
weights
≥
200 lb and will turn off at weights
≤
150 lb.
Note: The maximum value of the Dead Zone can
not exceed the set point value. The error
message “TOO BIG” will display.
11) Push
ENTER
to set the Dead Zone value.
This is the end of the value entry for a set
point. Now other parameters for set points
can be entered.
12) This step is optional, skip to step 16 if a
time delay is not needed. Push the
UP
key
to the “DELAY” menu.