M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L
Page 18
MSI-3750 Digital Weight Indicator
◆
User Guide
PEAK HOLD (FUNCTION KEY OPTION)
Allows monitoring peak weight. Uses a special mode of the A/D converter for
capturing transient events.
To Capture Peak Weight Readings
1)
Program a FUNCTION key for “PEAKHOLD” (See Section 2).
2)
Turn on the Peak Hold mode by pushing the selected FUNCTION key. The
display reads “PEAK NET” or “PK GROSS” to indicate peak hold mode is
enabled. The display will only update when a greater value than previously
recorded is detected.
To Clear Peak Weight Readings
Turn off the Peak mode by pushing the FUNCTION key programmed as
“PEAK HOLD”. The 3750 reads “PEAK OFF” and clears the peak value from
memory. The display will revert to NET or GROSS mode.
Note: Peak Hold captures data at a reading rate of 7.5 times per second. It has a full
scale step time constant of approximately 150ms. This function is not suitable for high
speed dynamic testing.
SELECT UNITS
LBS-OZ
GRAMS
OUNCES
METRIC T
TONS
KILOGRAM
POUNDS
ON
OFF
EXIT
SETUP
!
UNITS
F5
Содержание MSI-3750
Страница 145: ......