MAIN CONNECTOR DIGITAL I/O REGISTER
BADR3 + 1
READ
DI0, EXT TRIG, EXT PACER, EXT GATE
DI1
DI2, CTR0 GATE
DI3
0
0
0
0
0
1
2
3
4
5
6
7
The signals present at the inputs are read as one byte, the most significant 4 bits of which are always
zero. Digital Inputs 2 and 0 have multiple functions. Digital Input 2 may also be used as the gate to
Counter 1 of the 82C54 which is available on the Main connector, please see BADR3+6 for a more
detailed description. Digital Input 0 may also be used as either a trigger, a pacer, or a gate for the ADC,
please see BADR3+5 for a more details.
WRITE
DO0
DO1
DO2
DO3
X
X
X
X
0
1
2
3
4
5
6
7
The upper four bits are ignored. The lower four bits are latched TTL outputs. Once written, the state of
the inputs cannot be read back because a read back would read the separate digital input lines (see
above).
NOTE The digital lines 0-3, pins 3, 4, 5, 6, 22, 23, 24, & 25 of the analog connector
should not be used as ON/OFF Digital I/O. See below.
The digital inputs have multiple functions as described above. The digital outputs are also used by the
CIO-EXP32, 32 channel analog multiplexor/amplifier. There is a 24-line 82C55 on general purpose
digital I/O, see BADR4. We suggest that the Main connector 4-bit ports be kept free for analog
multiplexing control lines
.
ADC CHANNEL STATUS AND SWITCH SETTINGS REGISTERS
BADR3 + 2
READ ONLY
MA0
MA1
MA2
MA3
CLK
MUX
U/B
EOC
0
1
2
3
4
5
6
7
EOC = 1, the A/D converter is busy.
EOC = 0, it is free.
EOC is in both BADR3+2 and BADR3+3 for convenience in software programming.
U/B = 1, the Analog Input Polarity Switch is set to Unipolar.
U/B = 0, the Analog Input Polarity Switch is set to Bipolar
MUX = 1, the Analog Input Mode Switch is set to 16 single-ended.
MUX = 0, the Analog Input Mode Switch is set to 8 differential.
CLK = 1, the Pacer Clock Jumper is set to 10 MHz
CLK = 0, the Pacer Clock Jumper is set to 1 MHz.
24
Содержание PCIM-DAS1602/16
Страница 4: ...This page is blank ...
Страница 48: ...For your notes 44 ...