MDS 05-3305A01, Rev. B
MDS 4710/9710 I/O Guide
35
Spurious
Response Rejection:
70 dB
Intermodulation
Response Rejection:
65 dB
Receiver Spurious
Conducted Emissions:
–57 dBm, 9 kHz to 1 GHz
–47 dBm, 1 GHz to 12.5 GHz
Receiver Spurious
Radiated Emissions:
–57 dBm, 30 MHz to 1 GHz
–47 dBm, 1 GHz to 12.5 GHz
Bandwidth:
MDS x710A: 12.5 kHz
MDS x710C: 25 kHz
PRIMARY POWER
Voltage:
13.8 Vdc Nominal (10.5 to 16 Vdc)
TX Supply Current:
2.5 amps
RX Supply Current:
Operational—150 mA
Standby (sleep)—25 mA
Power Connector:
2-pin polarized locking connector
Fuse:
4 Amp Polyfuse, Self-Resetting, Internal
(Remove Primary Power to Reset)
Reverse Polarity Protection:
Diode across primary input
ENVIRONMENTAL
Humidity:
95% at 40 degrees C
Temperature Range:
–30 to 60 degrees C (full performance)
–40 to 70 degrees C (operational)
Weight:
1.6 kilograms
Case:
Die-cast Aluminum
DIAGNOSTICS INTERFACE
Signalling Standard:
RS-232
Connector:
RJ-11 (may use DB-25 instead if Pin 23 is grounded
to enable diagnostics channel)
I/O Devices:
MDS Hand Held Terminal or PC with MDS software
1.
Normal refers to:
Temperature, +15 to +35 degrees C
Humidity, 20% to 75%
Voltages, Nominal Specified
2.
Extreme refers to:
Temperature, –25 to +55 degrees C
Humidity, 20% to 75%
Voltages, ±10%