McQuay IM 487-4
57
Wiring Diagrams
Wiring Diagrams
Legend
ID
Description
Standard location
ACT3, 4
Actuator motor, economizer
Economizer section
ACT5
Actuator motor, discharge
isolation damper
Discharge section
ACT6
Actuator motor, return air
isolation damper
Return section
ACT7
Actuator motor, heat face/
bypass
Coil section, heat
ACT8
Actuator motor, cool face/
Bypass
Coil section, cool
ACT10,
11
Actuator motor, exhaust
dampers
Return section
ACT12
Actuator motor, enthalpy wheel
bypass damper
Energy recovery section
AFD10
Adjustable frequency drive,
supply fan
AFD/supply fan section
AFD11
Adjustable frequency drive,
evap cond. fans
Main/RCE control box
AFD20
Adjustable frequency drive,
return/exhaust fan
AFD/ret. ex. fan section
AFD60
Adjust. freq. drive, energy
recovery wheel(s)
Energy recovery section
AS
Airflow switch, burner blower
Gas heat box
BM
Burner blower motor
Heat section, gas
C10
Power factor capacitors,
supply fan
Supply Fan section
C20
Power factor capacitors, return
fan
Return section
CB10
Circuit breaker, supply fan
Main control box
CB11
Circuit breaker, evaporative
condenser fan(s)
Main/cond. control box
CB20
Circuit breaker, return/ exhaust
fan
Main control box
CB60
Circuit breaker, energy
recovery wheel
Main control box
CCB1, 2 Compressor control boards,
refrig. circuits
Main control box
CPC
Circuit board, main, micro
controller
Main control box
CPR
Circuit board, expansion, micro
controller
Main control box
DAT
Discharge air temperature
sensor
Discharge section
DFLH
Design flow lefthand sensor
Return section
DFRH
Design flow righthand sensor Return section
DHL
Duct hi-limit
Main control box
DS1
Disconnect, total unit or cond/
heat
Main control box
DS2
Disconnect, SAF/RAF/controls Main control box
DS3
Disconnect, electric heat
Electric heat box
EAT
Exhaust air temperature
sensor
Energy recovery section
EFT
Entering fan air temperature
sensor
Supply fan section
EHB1
Staged electric heat board
Main control box
ERB1
Energy recovery board
Main control box
ERM1
Energy recovery wheel motor
#1
Energy recovery section
ERM2
Energy recovery wheel motor
#2
Energy recovery section
F1A, B
Fuse, control circuit
transformer (T1), primary
Main control box
F1C
Fuse, control circuit
transformer (T1), secondary
Main control box
F2
Fuse, control circuit
transformer (T2), primary
Main control box
F3
Fuse, burner blower motor
Main control box
FB31–40 Fuseblock, electric heat (top
bank)
Electric heat box
FB41–50 Fuseblock, electric heat (bot.
bank)
Electric heat box
FD
Flame detector
Heat section, gas
FLC
Fan limit control
Heat section, gas
FP1, 2
Frost protection, refrig. circuits Coil section, cool
FS1, 2
Freezestat control
Coil section, heat/cool
FSG
Flame safeguard
Gas heat box
GCB1
Generic condenser board,
refrig. circ.
Main control box
GFR1, 2 Ground fault relay
Main control box
GFS1, 2 Ground fault sensor
Main control box
GRD
Ground
All control boxes
GV1
Gas valve, pilot
Heat section, gas
GV2
Gas valve, main/safety
Heat section, gas
GV3
Gas valve, redundant/safety
Heat section, gas
GV4–8
Gas valve, main, hi turn down Heat section, gas
HL1–10
Hi-limits, pwr, elec heaters (top
bank)
Heat section, electric
HL11–20 Hi-limits, pwr, elec heaters
(bot. bank)
Heat section, electric
HL22
Hi-limits, gas heat (pre-filters) Supply fan section
HL23
Hi-limits, gas heat (final filters) Final filter section
HL31–40 Hi-limits, ctl. elec heaters (top
bank)
Heat section, electric
HL41–50 Hi-limits, ctl. elec heaters (bot.
bank)
Heat section, electric
HP5
Hi-pressure controls, gas
Heat section, gas
HS1
Heat switch, electric heat
shutdown
Main control box
HS3
Heat switch, electric heat
deadfront interlock
Electric heat box
HTR65
Heater, sump
Evap. condenser section
HTR66
Heater, vestibule
Evap. condenser vestibule
HUM1
Humidstat sensor
Energy recovery section
IT
Ignition transformer
Gas heat box
LAT
Leaving air temperature sensor Energy recovery section
LP5
Low-pressure control, gas
Heat section, gas
LR10
Line Reactor, supply fan
Inverter bypass box
LR20
Line reactor, return/exhaust fan Inv. bypass/main cont. box
LS1, 2
Limit switch, low fire, high fire Gas heat box
LT10–23 Light, cabinet sections
Supply fan section
ID
Description
Standard location
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание RoofPak RAH 047C
Страница 118: ...McQuay IM 487 4 115 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 119: ...116 McQuay IM 487 4 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 120: ...McQuay IM 487 4 117 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...