14
ITEM
USAGE
Termination
Switches
The switches provide line termination configuration.
Jumper for
NMEA2000 shield
and ground
The jumper’s purpose is to wire together NMEA2000 cable’s shield
and ground. Depending on your scenario, you may choose not to
connect them together.
3.9 Connecting Extension Cable
Use the 37-pin- extension cable (1.8M) provided in the package connect Smartfind M5 to the
junction box.
Figure 10
Connecting Smartfind M5 with Junction Box
Termination off
Termination on
15
3.10 Configuring Smartfind M5
The following items must be completed before initial configuration.
1. Ensure VHF and GPS antennas are connected to the transponder main unit.
2. Ensure the 37-pin-connector extension cable is connected from the transponder main unit
to the junction box.
3. Ensure the power cable is connected and supplied with stable voltage/current power
source.
4. Ensure applicable external devices are connected through the junction box.
3.10.1 Initial Configuration
The initial configuration, particular,
MMSI
(Maritime Mobile Service Identity) number must be done
before operation. The following initial configuration is required:
1. Setup 1:
MMSI
should be correctly programmed.
Figure 11
Built-in Test
2. Step 2: Press
MENU
and select main menu item
SHIP SETTING
. (Password required, default
is
“0000”
)
Power…………………..…….…………[PASS]
Flash..…………………..…….…………[PASS]
Built-in Test
Transmission inhibited!
Only Receiving Function available!
Set MMSI right now?
YES
NO
MMSI unregistered