background image

2

déconnecter le cordon d’alimentation de l’adaptateur AC/

DC de la prise murale.

18. 

WARNING: 

Do not expose batteries or battery pack to 

excessive heat such as sunshine, fire or the like.

AVERTISSEMENT: 

Les batteries ou bloc de batter-

ies ne doivent pas etre exposees a une chaleur excessive 

telle que celle du soleil, feu ou autre source de chaleur 

similaire.

19. 

CAUTION:

 danger of explosion if battery is incorrectly 

replaced. Replace only with the same or equivalent type.

ATTENTION: 

danger d’explosion si la pile n’est pas 

remplacée correctement. Ne remplacer que par le même 

type ou un type équivalent.

20. Connect mains power supply cord only to a mains socket 

outlet with a protective earthing connection.

21. 

WARNING: 

The Ethernet connector of this equipment 

must not be directly connected to a public network. Con-

nection is to be made only by way of a modem or router 

approved for this purpose.

14. 

Refer all servicing to qualified service personnel. Servicing 

is required when the apparatus has been damaged in any 

way, such as power-supply cord or plug is damaged, liquid 

has been spilled or objects have fallen into the apparatus, 

the apparatus has been exposed to rain or moisture, does 

not operate normally, or has been dropped.

15. Do not expose this equipment to dripping or splashing and 

ensure that no objects filled with liquids, such as vases, 

are placed on the equipment.

Ne pas exposer cet appareil à des éclaboussures ou 

gouttelettes d’un liquide.  Aucun objet remplie de liq-

uide comme par exemple un vase ne doit être placé sur 

l’appareil.

16. If this equipment is supplied with a power supply cord 

only, the mains plug of the power supply cord shall remain 

readily operable. To completely disconnect this equipment 

from the a.c. mains remove the plug from the a.c. recep-

tacle.

Si l’équipement est uniquement alimenté par un cordon 

d’alimentation, la fiche du cordon d’alimentation doit de

-

meurer aisément accessible.   Pour déconnecter complète-

ment l’équipement du réseau d’alimentation, déconnecter 

la fiche du cordon d’alimentation de la prise murale.

17. If this equipment is supplied with AC /DC Adapter with 

separate power supply cord or the AC/DC Adapter plug-

ging directly into an a.c. receptacle, they shall remain 

readily operable. To completely disconnect this equipment 

from the a.c. mains remove the AC /DC Adapter mains 

power supply cord from the a.c. receptacle or remove the 

AC /DC Adapter when it is directly plugged into the a.c. 

receptacle.

Si l’équipement est alimenté par un adaptateur AC/DC 

munis d’un cordon d’alimentation ou un adaptateur AC/

DC qui est alimenté directement à la prise murale, ils 

doivent demeurer aisément accessibles. Pour déconnecter 

complètement l’équipement du réseau d’alimentation, 

déconnecter l’adaptateur AC/DC de la prise murale ou 

1. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with a dry cloth.

7. Do not block any ventilation openings. Install in accordance 

with the manufacturer’s instructions.

8. Do not install near any heat sources such as radiators, heat 

registers, stoves, or other apparatus (including amplifiers) 

that produce heat.

9. Do not defeat the safety purpose of the polarized or ground-

ing-type plug. A polarized plug has two blades with one 

wider than the other. A grounding type plug has two 

blades and a third grounding prong. The wide blade or the 

third prong are provided for your safety. If the provided 

plug does not fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched 

particularly at plugs, convenience receptacles, and the 

point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manu

-

facturer.

12. Use only with the cart, stand, tripod, bracket, 

or table specified by the manufacturer, or sold 

with the apparatus. When a cart is used, use 

caution when moving the cart/apparatus com-

bination to avoid injury from tip-over.

13. Unplug this apparatus during lightning storms or when 

unused for long periods of time.

T

he lightning flash with arrowhead, within an equilateral triangle, 

is intended to alert the user to the presence of uninsulated “dan

-

gerous voltage” within the product’s enclosure that may be of suf

-

ficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to 

alert the user to the presence of important operating and mainte

-

nance (servicing) instructions in the literature accompanying the 

appliance.

ATTENTION:

RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR

WARNING - TO REDUCE RISK OF FIRE OR 

ELECTRICAL SHOCK, DO NOT EXPOSE 

THIS EQUIPMENT TO RAIN OR MOISTURE.

NO USER-SERVICEABLE PARTS INSIDE. 

REFER SERVICING  

TO QUALIFIED PERSONNEL.

To prevent the risk of electric shock, 

do not remove cover or back. No 

user-serviceable parts inside.

IMPORTANT SAFETY 

INSTRUCTIONS!

PLEASE READ THEM  

BEFORE OPERATING THIS EQUIPMENT.

WARNING

The McIntosh C12000 is a two chassis design,  

with separate Preamplifier and Controller chassis. 

There are custom interconnecting cables  

and custom chassis sockets used  

to connect the two chassis together.

Use ONLY the custom interconnect cables supplied 

with the C12000 to connect the chassis together.

Do NOT connect the C12000 Left and Right  

25-Pin Chassis Sockets to any other component.

Failure to observe this warning  

will result in damage to the components connected.

Содержание C12000 Controller

Страница 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com C12000 Controller C12000 Preamplifier Owner s Manual...

Страница 2: ...s ment accessibles Pour d connecter compl tement l quipement du r seau d alimentation d connecter l adaptateur AC DC de la prise murale ou 1 Read these instructions 2 Keep these instructions 3 Heed al...

Страница 3: ...ify your purchase from this information if the occasion should arise Serial Number _______________________________ Purchase Date _______________________________ Dealer Name ___________________________...

Страница 4: ...o or more IR sensors need to be connected to the C12000 The signal from a connected External IR Sensor will have priority over the signal from the Front Panel IR Sensor 9 Controller to Preamplifier Ca...

Страница 5: ...ital Logic integrated circuits drive Electromagnetic Switches on all Inputs and operating functions for reliable noiseless distortion free switch ing All the Inputs on the C12000 can be matched in lev...

Страница 6: ...RTED PARTS C12000 CONTROL L ER LEFT OUTPUT TO C12000 PREAMPLIFIER LEFT INPUT RIGHT OUTPUT TO C12000 PREAMPLIFIER RIGHT INPUT 120V 50 60Hz 75 WATTS POWER CONTROL MAIN OUT 1 TRIG 3 TRIG 1 PASSTHRU OUT 2...

Страница 7: ...t the coolest possible operating temperature A custom cabinet installation should provide the following minimum spacing dimensions for cool operation Allow at least 6 inches 15 2cm above the top 2 inc...

Страница 8: ...HANDCRAFTED IN USA WITH US AND IMPOR TED P AR TS C 12000 P R E A MP L IF IE R 2 1 SS PH1 MAIN REC FIXED 3 1 2 4 PH2 1 2 T 4 3 6 5 PH1 3 1 2 4 PH2 4 3 6 5 2 1 SS MAIN REC FIXED 1 2 T 17 1 2 44 5cm 5 3...

Страница 9: ...ntaining all the system components at the coolest possible operating temperature A custom cabinet installation should provide the following minimum spacing dimensions for cool operation Allow at least...

Страница 10: ...Connect the C12000 Controller power cord to a live AC outlet Refer to information on the back panel of your C12000 Controller to determine the correct voltage for your unit 8CR RIGHT OUTPUT Connector...

Страница 11: ...m setting with the Front Panel Controls or Remote Control Push Buttons Output 1 1 SS uses Solid State amplification Output 2 2 T uses Tube Amplification 9PR LEFT OUTPUT MAIN Unbalanced sends signals t...

Страница 12: ...efaut settings POWER CONTROL OUT 1 and 2 are active by default They can be switched On Off by using the C12000 Controller TRIM Function 7 Optionally connect a Control Cable from the C12000 Controller...

Страница 13: ...amplifier RIGHT INPUT Socket In a similar manner connect the second cable from the C12000 Controller LEFT OUTPUT Socket to the C12000 Input Assignment Chart Preamplifier LEFT INPUT Socket AC Power Cor...

Страница 14: ...wn Navigate backwards through the current active media using this button This is also used to adjust the tuner downwards 22 23 24 14 Fast Forward Seek Up Navigate forward through the current active me...

Страница 15: ...ode allowing changes to the default settings 8C HXD Push button with indicator activates the Crossfeed Director Circuitry for Headphones 9C MUTE Push button mutes the audio from the Loudspeakers and H...

Страница 16: ...ital Audio Player Turntable with Moving Coil Cartridge AM FM Tuner Media Bridge SACD CD Player IR Sensor To C12000 Preamplifier Left Input To C12000 Preamplifier Right Input Connection Legend Data Cab...

Страница 17: ...rntable with Moving Coil Cartridge AM FM Tuner Media Bridge SACD CD Player From C12000 Controller Left Output From C12000 Controller Right Output Connection Legend Data Cable Digital Signal Cable Sens...

Страница 18: ...Loudspeaker System Right Loudspeaker System Left Loudspeaker System Power Amplifier Primary Room Connection Legend Data Cable Digital Signal Cable Sensor Keypad Cable Ground Wire Power Control Cable...

Страница 19: ...hannel Main Room Partial View Power Amplifier Right Front Channel Main Room Partial View Connection Legend Data Cable Digital Signal Cable Sensor Keypad Cable Ground Wire Power Control Cable Audio Sig...

Страница 20: ...er Setup Mode 2 Referring to the Front Panel Information Display the number after the character V is the Firmware number Refer to figure 2 3 To exit the Setup Mode press the SETUP Push button Input Se...

Страница 21: ...on Page 20 10 Exit the SETUP Mode by pressing the SETUP Push button RENAME INPUT In the following example the Balanced 1 Input will be renamed to match up with the component con nected The C12000 Def...

Страница 22: ...buttons on the Remote Control If it is desirable to have OUTPUT 1 and or 2 always On regardless of the TRIM setting perform the following 1 Press the SETUP Push button to enter the SETUP MODE Refer to...

Страница 23: ...be assigned to Data Port 1 perform the following Steps 1 Press the SETUP Push button to enter the SETUP MODE Refer to figure 2 2 Rotate the TRIM Control until SETUP Data Port 1 All Data appears on th...

Страница 24: ...ssing the SETUP Push button Comm Port Baud Rate The C12000 may be remotely controlled from other equipment connected to the Rear Panel RS232 Jack The speed at which the C12000 communicates 8 bit no pa...

Страница 25: ...bled 4 Exit the SETUP Mode by pressing the SETUP Push button Factory Reset If it becomes desirable to reset all the adjustable set tings Setup and Trim Settings to the factory default values perform t...

Страница 26: ...e setting for OUTPUT 1 or OUTPUT 2 Refer to figures 60 thru 62 Figure 60 OUTPUT 1 OFF Figure 61 OUTPUT 2 ON Figure 62 OUTPUT 2 OFF Note The OUTPUT 1 and OUTPUT 2 Remote Control Push buttons may also b...

Страница 27: ...rs will also switch On Off when connected to the C12000 via a power control cable 2 Some A V Processors will provide an On Off Con trol Signal when the C12000 Passthru Input Jack is connected to the A...

Страница 28: ...record level using the recorder level con trol and proceed with the recording process 3 Listen to the playback of the program source just recorded by selecting the Input Source connected to the recor...

Страница 29: ...Solid State OR Tube Change which circuitry the Main Output uses Solid State or Tube This example assumes the Main Output is currently set to Solid State Perform the following steps to change the circ...

Страница 30: ...From Main Output 16 40 ohms 0dB 40 150 ohms 6dB 150 600 ohms 12dB Headphone Output 150mW minimum from 16 ohms to 600 ohms load Power Control and Trigger Output 12VDC 25mA Tube Complement 10 Tubes Six...

Страница 31: ...ondition If a shipping carton or any of the interior part s are needed please call or write Customer Service Department of McIntosh Laboratory Refer to Page 3 Please see the Part List for the correct...

Страница 32: ...cts is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice Printed in the U S A McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www mcin...

Отзывы: