![McElroy In Field Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/mcelroy/in-field/in-field_operators-manual_1754768023.webp)
4 - 2
Maintenance
Fasteners Must Be Tight
Check all nuts, bolts, and snap rings to make certain they are
secure and in place.
TX00437-9-13-94
Bleeding the Hydraulic System
Make sure the hydraulic pump fluid has been filled and tilt the
machine 45 degrees so that the pump is facing up.
Pump the machine moving the cylinder in and out completely
several times.
When bled, the machine should move immediately when
pumped. Any pause may indicate that there is air still in hydraulic
system. Repeat the pumping of the machine and then check the
pump again.
If the cylinder moves immediately then there is no air left in the
system.
TX04086-5-25-10