Hydraulic Fluid Reservoir (Acrobat HPU)
The reservoir is incorporated in the HPU. The fluid level should be
up to the fill plug on the end of the reservoir when the reservoir is
on level ground.
Never allow dirt or other foreign matter to enter the open tank.
Refer to the "Hydraulic Fluids" section of this manual for hydraulic
fluid recommendations.
TX04793-12-12-16
CD014
00
-10
-5-15
Acrobat Hydraulic Power Unit (HPU)
The Acrobat HPU consists of three main hydraulic components:
1. Power pack - Consists of a capacitor start electric motor not
submerged and gear pump that is submerged in the fluid reservoir to
aid in cooling and reduce noise.
2. Hydraulic accumulator - Allows the power pack to cycle on
and off to meet the demands of the hydraulic system, which reduces
noise and power consumption.
3. Carriage control box - Includes all the McElroy standard
carriage controls.
DataLogger® port
Pressure gauge
Hour meter
Carriage Control Box
Filter Bypass Indicator
Electric motors are not explosion proof. Operation of
these components in an explosive atmosphere will result
in serious injury or death. Refer to Special Operation -
Fusion in Explosive Atmosphere for safety precautions.
TX04792-05-05-16
CD019
41-0
2-
07
-17
CD019
40
-0
2-
07
-17
¡PELIGRO!
Overview
2 - 3
Filter (Acrobat HPU)
This HPU is equipped with a 3 micron pressure filter located under
the top cover of the HPU below the filter bypass indicator.
If the filter bypass indicator is activated, the hydraulic fluid is
bypassing the filter and the fluid and filter need to be changed.
TX04794-02-21-17
CD019
42
-0
2-
07
-17
B
B
D
D
E
A
A
E
C
C
Содержание A714201