Heating the Pipe
A
) Verify that the pressure selector control is in the fusing
position.
B
) Close the carriage to bring pipe ends in contact
with the heater. Allow for bead-up according to
pipe manufacturer's or appropriate joining standard
recommendations.
Ensure the heater stays perpendicular to the pipe by
supporting the heater during the heating process.
C
) After proper bead-up, move pressure selector control to
middle (heating mode) position and leave the carriage
directional control in the closed position.
NOTICE:
Ensure that the pipe remains in contact with
heater throughout the entire process. If the pipe
loses contact with the heater, abort the joint and
go to ”Attach Carriage to Pipe”.
TX04827-05-05-16
CD014
35-11-16
-15
0
100
200
300
400
500
600
700
800
900
1000
DIRECTIONAL
CONTROL
VALVE
FACING
PRESSURE
HEATING
PRESSURE
FUSING
PRESSURE
SELECTOR
VALVE
0
100
200
300
400
500
600
700
800
900
1000
DIRECTIONAL
CONTROL
VALVE
FACING
PRESSURE
HEATING
PRESSURE
FUSING
PRESSURE
SELECTOR
VALVE
0
100
200
300
400
500
600
700
800
900
1000
DIRECTIONAL
CONTROL
VALVE
FACING
PRESSURE
HEATING
PRESSURE
FUSING
PRESSURE
SELECTOR
VALVE
Special Operations - Vertical Fusion (Movable Pipe Below)
4 - 8
CD013
84
-10
-5-15
B
A
C
FUSES
MOTOR
POWER
SUPPLY
CD018
92
-12
-0
7-16
A
C
B
Acrobat HPU
DynaMc EP HPU
Содержание A714201