Opening Jaws
After the joint has cooled for the pipe manufacturer's
recommended time or appropriate joining standard, shift the
carriage directional control to the neutral position.
Turn off HPU.
Loosen all clamp knobs. Turn on HPU and open the carriage.
Open all of the jaws.
TX04815-05-05-16
CD013
42
-10
-5-15
Position Pipe for Next Joint
Move the fusion machine to end of pipe, or pull the pipe through
the jaws until the end of the pipe is protruding approximately 1"
(25.4mm) past the fixed jaw.
TX04816-12-01-15
Install Next Piece of Pipe
Open the carriage completely.
Insert a new piece of pipe in movable jaws and repeat all
previous steps in the procedures.
TX04817-11-18-15
CD013
43-10
-5-15
CD013
42
-10
-5-15
Butt Fusion Procedure
3 - 14