Clean Surfaces
Use 50 or 60 grit utility cloth to clean and rough the main to expose fresh
material.
Rough the base of the fitting unless the manufacturer specifies otherwise.
TX00460-9-16-94
Check Heater
Use a Pyrometer and verify that the heater is at proper temperature. Refer
to the pipe manufacturer's recommended procedures.
Use a clean non-synthetic cloth to clean the heater adapter surfaces.
TX01048-7-22-96
Saddle Fusion Procedure
Clamp Fitting
Position the fitting loosely in the movable jaw and move fitting against the
main. Make sure fitting is properly seated on the main and tighten jaw
clamp.
TX01046-7-22-96
Test for Slippage
Bring the fitting against the main under pressure to ensure that no slippage
or movement of the main or fitting occurs.
TX01047-7-22-96