B
Event Group
B-55
FC Management MIB
connUnitPortStatCountClass1FRJTFrames
Syntax
OCTET STRING (SIZE (8))
Access
read-only
Status
mandatory
Description
Count of times that FRJT was returned to this port as a result of a
Class 1 Frame that was rejected by the fabric. Note, this is a Fibre
Channel only stat.
Sequence
::= { connUnitPortStatEntry 18 }
connUnitPortStatCountClass1PRJTFrames
Syntax
OCTET STRING (SIZE (8))
Access
read-only
Status
mandatory
Description
Count of times that FRJT was returned to this port as a result of a
Class 1 Frame that was rejected at the destination N_Port. Note, this
is a Fibre Channel only stat.
Sequence
::= { connUnitPortStatEntry 19 }
connUnitPortStatCountClass2RxFrames
Syntax
OCTET STRING (SIZE (8))
Access
read-only
Status
mandatory
Description
Count of Class 2 Frames received at this port. Note, this is a Fibre
Channel only stat.
Sequence
::= { connUnitPortStatEntry 20 }
connUnitPortStatCountClass2TxFrames
Syntax
OCTET STRING (SIZE (8))
Access
read-only
Status
mandatory
Содержание 316095-B21 - StorageWorks Edge Switch 2/24
Страница 1: ...E OS SNMP Support Manual P N 620 000131 630 REV A ...
Страница 22: ...1 1 10 E OS SNMP Support Manual Introduction to SNMP ...
Страница 117: ...2 Fabric Element Management MIB 2 95 McDATA SNMP Support NOTE All the counters are 32 bit counters ...
Страница 248: ...A A 78 E OS SNMP Support Manual Fibre Alliance MIB ...
Страница 324: ...B B 76 E OS SNMP Support Manual FC Management MIB ...
Страница 380: ...C C 56 E OS SNMP Support Manual McDATA Private Enterprise MIB ...
Страница 500: ...F F 10 E OS SNMP Support Manual SNMP Framework MIB ...