A
FA MIB
A-47
Fibre Alliance MIB
EOF. FC loop devices should not count frames passed through. This
value represents the sum total for all other Rx objects.
Sequence
::= { fcConnUnitPortStatEntry 4 }
fcConnUnitPortStatTxElements
Syntax
Counter64
Max-Access
read-only
Status
current
Description
The number of octets or bytes that have been transmitted by this port.
One second periodic polling of the port. This value is saved and
compared with the next polled value to compute net throughput.
Note, for Fibre Channel, ordered sets are not included in the count.
Sequence
::= { fcConnUnitPortStatEntry 5 }
fcConnUnitPortStatRxElements
Syntax
Counter64
Max-Access
read-only
Status
current
Description
The number of octets or bytes that have been received by this port.
One second periodic polling of the port. This value is saved and
compared with the next polled value to compute net throughput.
Note, for Fibre Channel, ordered sets are not included in the count.
Sequence
::= { fcConnUnitPortStatEntry 6 }
fcConnUnitPortStatBBCreditZero
Syntax
Counter64
Max-Access
read-only
Status
current
Description
Count of transitions in/out of BBcredit zero state. The other side is
not providing any credit. Note, this is a Fibre Channel stat only.
Sequence
::= { fcConnUnitPortStatEntry 7 }
Содержание 316095-B21 - StorageWorks Edge Switch 2/24
Страница 1: ...E OS SNMP Support Manual P N 620 000131 630 REV A ...
Страница 22: ...1 1 10 E OS SNMP Support Manual Introduction to SNMP ...
Страница 117: ...2 Fabric Element Management MIB 2 95 McDATA SNMP Support NOTE All the counters are 32 bit counters ...
Страница 248: ...A A 78 E OS SNMP Support Manual Fibre Alliance MIB ...
Страница 324: ...B B 76 E OS SNMP Support Manual FC Management MIB ...
Страница 380: ...C C 56 E OS SNMP Support Manual McDATA Private Enterprise MIB ...
Страница 500: ...F F 10 E OS SNMP Support Manual SNMP Framework MIB ...