Installation and use
SOLID CONTROL MCK 2200
8
4. Operation
Once the MCK 2200 computer has been connected to the power supply, the green
LED (ref.C) "CHARGED BATTERY" will light up.
Pressing the ON/OFF key (ref.A) will allow you to turn on the computer, which will
perform a 2-second operating test, while keeping all segments of the display and the
LEDs on. After the test, the computer will show the operating hours accumulated up to
that moment and will then be ready to work or receive new settings.
The function of the individual parts is explained below.
4.1
Display
The display can be show the following values:
4.1.1
Number of
partial plants (REF. O5)
The partial plants are counted by means of the function of the left and right solenoid
valve outputs. Every 2 activations of an output correspond to the increase of 1 plant,
since each plant must be sprayed on both sides (i.e. 2 activations of the output).
To display it, position the arrow on the "n° of partial plants" symbol by means of the
"SELECT" key (ref. F). To reset this value, when it is shown on the display, keep the
"SELECT" key pressed until "0" appears on the display.
O1 O2
O4
O3
O5
O8
O6
O7
O9