Installation and use
SOLID CONTROL MCK 2200
6
Ref
.
Description
INput / OUTput
signal type
Connector
reference
N
Right AUTO/MAN key with green LED
--
--
OR
5-digit LCD display with green LED back-
lighting to view:
Number of total plants
--
--
Number of partial plants
--
--
Working pressure (only full opt. version art.
4494)
IN (4
20mA)
5C
Distributed litres
IN (NPN NO)
4C
Litres left
--
--
Status of the right sensor (ON-OFF)
IN (PNP NO)
3C
Status of the left sensor (ON-OFF)
IN (PNP NO)
2C
Status of the right solenoid valve (ON-OFF)
OUT (+Vb*)
8A
Status of the left solenoid valve (ON-OFF)
OUT (+Vb*)
8C
Programming parameters
--
--
Working hours
--
--
General solenoid valve (only full opt. version
art. 4494)
OUT (+Vb*)
1A
Sensor power supply
OUT (+Vb*)
7B, 7C
Sonar power supply
OUT (+24V**)
6B, 6C
Sensor earth
OUT (-)
3B, 4B, 5B
Solenoid valve earth
OUT (-)
2A, 2B, 1C,
Computer positive power supply
IN (+Vb*)
8B
Computer negative power supply
IN (-)
1B
Not connected
3A, 4A, 5A
Vb* = Power supply voltage 10 ÷ 16 Vdc
+24V**=This value is only guaranteed if the monitor is powered within the range
10 ÷ 16 Vdc.