background image

DPA 
 
 

 

 
 
 
 
 
 
 
 

SOLID CONTROL  

MCK 2200 

COMPUTER FOR SPRAYERS 

INSTRUCTIONS FOR USE 

NR.ST2621-EN 

REV. 3 

 

EN 

 

Содержание MCK 2200

Страница 1: ...DPA SOLID CONTROL MCK 2200 COMPUTER FOR SPRAYERS INSTRUCTIONS FOR USE NR ST2621 EN REV 3 EN...

Страница 2: ...O ITALY Tel 39 0425 754713 Fax 39 0425 741130 E mail mcstaff mcelettronica it Internet www mcelettronica it Manual code ST2621 EN Issued July 2013 Edition October 2021 MC elettronica S r l is not obli...

Страница 3: ...3 Working pressure ref O7 9 4 1 4 Distributed litres ref O8 9 4 1 5 Litres left ref O9 9 4 1 6 Sensor status ref O1 and O4 9 4 1 7 Solenoid valve status ref O2 and O3 10 4 1 8 Working hours 10 4 2 IZ...

Страница 4: ...ted by the Customer before starting the mass production The electronic board of the MCK 2200 computer is treated with silicone resin to increase its resistance to possible infiltration of humidity or...

Страница 5: ...SELECT RESET key for display indications and totalisers reset G General AUTO MAN key with green LED H PROG key for constants programming I Right START STOP key with red LED L key to decrease the valu...

Страница 6: ...3C Status of the left sensor ON OFF IN PNP NO 2C Status of the right solenoid valve ON OFF OUT Vb 8A Status of the left solenoid valve ON OFF OUT Vb 8C Programming parameters Working hours General sol...

Страница 7: ...en printed polyester B Self extinguishing ABS box closing black frame C Self extinguishing ABS grey container D Connector for signals and power supply E Fastening knobs F Self extinguishing ABS grey s...

Страница 8: ...or receive new settings The function of the individual parts is explained below 4 1 Display The display can be show the following values 4 1 1 Number of partial plants REF O5 The partial plants are c...

Страница 9: ...this To reset this value when it is shown on the display keep the SELECT key pressed until 0 appears on the display For the litres to be counted correctly the constant i must be set correctly see para...

Страница 10: ...oid valves can be switched one at a time from the automatic operating status to the manual operating status Simply press one of the two special keys ref B and N and the solenoid valves will switch to...

Страница 11: ...setting some constants described in the following paragraph N B Only in the case of the full opt art 4494 MCK 2200 model and during work out of the programming mode can an output be controlled by usin...

Страница 12: ...crements of 1 can be reset by pressing the RESET key ref F for 3 SECONDS while the number of partial plants is shown on the display ref O5 4 7 3 Total plants totaliser 0 to 99999 increments of 1 canno...

Страница 13: ...eous switch of the two sections to automatic mode the following key will be used ref E AUTO MAN GENERAL The enabling of this setting is indicated by the relative green LED going on This key ref E has...

Страница 14: ...and that of the plants partial and total takes place in the same way as the automatic mode Even in this case the key ref G has priority over the status of the two sections when the following is press...

Страница 15: ...15 CAUTION DO NOT WASH USING A POWER WASHER WITH PRESSURE JET WARNING THIS PRODUCT CONTAINS TIN AND LEAD IT MUST BE DISPOSED OF AT THE END OF ITS LIFE CYCLE AT THE DESIGNATED DISPOSAL FACILITIES OR DE...

Страница 16: ...Printed in Italy Electronic equipment for agriculture www mcelettronica it...

Отзывы: