Soiling Station Diagnostics
Configuration and operation of MBSoiling Station is quite simple. It can be easily
configured using the default settings.
Some of the probable problems and solutions are listed below.
10.1
Download Device Status and Values Report:
Download status report and logged messages as shown in sec. 7.7.1. and sec. 7.7.2.
This report will enable better understanding of the problem.
10.2
Embedded Webserver
Sr. No.
Problem
Solutions
1
Unable to login to Device
i)
Check that proper IP set in the device is
being used.
ii)
Try default device IP.
iii)
Confirm that there is no IP clash in the
network.
iv)
Check that IP set is as per network
class.
v)
If user has closed the webpage without
logout – wait for
about three minutes
before attempting next login.
2
Unbale to login.
Message ‘Soiling Station is
being configured. Login
after some time’.
This message is generated if user tries to login
while the device is being configured.
Try to login after 10 to 15 seconds.
Table-11.2: Embedded webserver problems
10.3
ETH Network
Sr. No.
Problem
Solutions
1
SNTP client not able to
update time.
i)
Check that network gateway has been
configured properly and connected to
the LAN. Check gateway status on
webserver diagnostics.
ii)
Check availability of internet.
iii)
Verify NTP server IP set in the Device.
vi)
Verify operation of the NTP server via
ping.
Table-9.3: ETH Network problems
10.4
Soiling Station Modem
Sr. No.
Problem
Solutions
1
Modem is unable to
register to network.
i)
Check cellular signal strength via
webserver diagnostic.