![MB 700 H Series Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/mb/700-h-series/700-h-series_operation-manual_1752089039.webp)
39
4.11
Configure – SNTP Client
SNTP client can be used to synchronize internal clock of the soiling station. The client
can be used to operate via datalogger network or internal modem.
Up-to NTP time servers can be configured. SNTP client will switch over to next time
server if any server fails to respond.
Left click on menu option ‘SNTP Client’ for configuration as shown in figure-4.11
below.
Figure-4.11: Configuration of SNTP client.
SNTP client will operate in ‘Client Mode’ only.
Configuration details of SNTP clients are provided in table 4.11 below.
Sr. No
Parameter
Description
Remarks
1
NTP Server IP
and URL
Configure NTP
server IP or URL.
Either of the two can
be configured.
SNTP client will get time from
any of the configured and
working NTP servers.
URL will be resolved if DNS
are configured.
Table-4.11: Configuration – SNTP Client
Notes:
i)
If SNTP client fails to get time via the configured media. It will try to change
the media (if alternate media is available) and get time.