![MB 700 H Series Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/mb/700-h-series/700-h-series_operation-manual_1752089061.webp)
61
8.3
Soiling Parameters
Sr. No
Parameter
Register Address
Type
Read/ Write
1
Soling Ratio
10602
32 bits float
Read only
2
Soling Ration – Day
average
10604
32 bits float
Read only
3
Soling Index (%)
10606
32 bits float
Read only
4
Soling Index (%) – Day
average
10608
32 bits float
Read only
5
Soiling measurement
time
10600
32 bits – unsigned
Read only
Table-8.3: Soiling parameters
8.4
Measurement Panel Parameters
Sr. No
Parameter
Register Address
Type
Read/ Write
1
Panel Clean Parameters
1.1
Effective Irradiation
(W/mtr2)
10610
32 bits float
Read only
1.2
Short Circuit Currents
(Amps)
10612
32 bits float
Read only
1.3
Voltage (V)
10614
32 bits float
Read only
1.4
Panel Temperature (⁰C)
10616
32 bits float
Read only
2
Panel Soiled Parameters
2.1
Effective Irradiation
(W/mtr2)
10618
32 bits float
Read only
2.2
Short Circuit Currents
(Amps)
10620
32 bits float
Read only
2.3
Voltage (V)
10622
32 bits float
Read only
2.4
Panel Temperature (⁰C)
10624
32 bits float
Read only
Table-8.4: Measurement panels parameters
8.5
Cleaning System Configuration Parameters
Applicable only for soiling stations with auto cleaning system.
Cleaning system configuration parameter registers.
Sr. No
Parameter
Register Address
Type
Read/ Write
1
Auto clean enable
b0: =1 for auto clean
enable
=0: for auto clean
disable
10650
16 bits Unsigned
Integer
Read / Write
23
Reference panel
cleaning time –
Hours (0-23)
10651
16 bits Unsigned
Integer
Read / Write
Содержание 700 H Series
Страница 8: ...8 M Soiling station with modem H Soiling station with high wattage solar panel...
Страница 19: ...19...