5
■
Branch connection procedure using electro tap
1. Insert the harness and vehicle wiring harness into
the electro tap.
2. Fold the electro tap as shown in the figure and lock
it.
3. Insert the harness to the end of the electro tap.
4. Firmly press the electro tap terminal using pliers.
5. Fold the electro tap in the direction of the arrow
shown in the figure and lock it.
6. Soundproof using urethane tape.
■
Branch connection procedure using electro-tap (Optional ON-OFF switch installed)
1. Put the harness to be branch-connected into the
guide groove.
2. Fold back the electro-tap from the A part as shown
in the figure.
3. Lock the electro-tap temporarily.
4. Firmly press the electro tap terminal using pliers.
Firmly engage the lock part until a click sound
is heard.
CAUTION
The temporary lock is provided on only one
side. Stop short of locking the final locks.
CAUTION
Pinch the electro-tap until a clicking sound is
heard from the final locks on the both sides.
CAUTION
Electro tap
Harness
Firmly press
using pliers
Vehicle wiring harness
Lock
Lock
Vehicle wiring harness
Terminal
Vehicle wiring harness
The terminal is embedded in the insulator. If it
is not, insert the terminal as shown in the figure
and press it in until it is securely fixed.
CAUTION
Terminal
Insulator
Guide groove
Harness
A
Temporary lock
Final lock