Maytag sav2655aw Скачать руководство пользователя страница 7

Motor Trouble Shooting

 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless 
testing requires it. 
 

October 2003 

16022616   Rev. 0 

 

Continuity exists between switch 

terminal 

R

 and Red wire.

Manually depress actuator. 

Continuity broken between 

switch terminal 

R

 and Red wire.

Continuity exists between switch 

terminal 

P

 and Red wire.

Manually depress actuator. 

Continuity broken between 

switch terminal 

P

 and Red wire.

Inoperative start switch. 

Replace motor.

Inoperative high speed 

switch. Replace switch.

Continuity broken between 

switch terminal 

P

 and Violet wire.

Manually depress actuator. 

Continuity exists between switch 

terminal 

P

 and Violet wire.

Inoperative low speed 

switch. Replace switch.

Motor switch checks OK.

NO

YES

YES

YES

YES

YES

YES

NO

NO

NO

NO

NO

    Start
Terminals

High Speed
Terminals

Low Speed
Terminals

One or Two Speed Motors

4-5 ohms between Brown wire 

and Red wire.

1-2 ohms between Blue wire and 

Yellow wire.

1-2 ohms between Yellow wire 

and Violet wire.

Continuity exists between Yellow 

wire and White wire.

All motor windings checks OK.

Inoperative start winding. 

Replace motor.

Inoperative high speed winding. 

Replace motor.

Inoperative low speed winding. 

Replace motor.

Inoperative common lead. 

Replace motor.

   Start
Winding

High Speed
  Winding

Low Speed
  Winding

Protector

NO

NO

NO

NO

YES

YES

YES

YES

Содержание sav2655aw

Страница 1: ...l RS3100007 for detailed installation operating testing troubleshooting and disassembly instructions CAUTION All safety information must be followed as provided in this Technical Sheet and in Service...

Страница 2: ...h for continuity between terminals See component testing Check timer contacts Check for continuity on water valve solenoid See component testing Vibration Weak floors can cause vibration and walking L...

Страница 3: ...y need to be purged prior to starting wash cycle Disconnect inlet hoses and clean screens Will Not Spin Check for unbalanced load Does the house drain system accept water from machine Check for blocke...

Страница 4: ...old Side 2 25 gpm Hot Side 2 00 gpm Mix 3 00 gpm at 30 120 psi Measure resistance of terminals on each valve Resistance across each valve 1000 10 Drain Pump Verify Drain Pump is not clogged or damaged...

Страница 5: ...Rinse Switch Disconnect wires from component to properly measure the resistance Place switch in the following positions and measure across the terminals below On YL YL Off Continuity 1 Infinite Temper...

Страница 6: ...washer before servicing unless testing requires it 16022616 Rev 0 October 2003 6 4 POLE MAIN Y E L L O W 6 POLE MAIN BLUE VIOLET RED B R O W N AUX WHITE PROTECTOR WHITE Y BU BR W P R G RUN START WIRI...

Страница 7: ...n switch terminal P and Violet wire Manually depress actuator Continuity exists between switch terminal P and Violet wire Inoperative low speed switch Replace switch Motor switch checks OK NO YES YES...

Страница 8: ...Pause 0 00 21 Spin medium 0 02 42 Spin Spray warm or cold medium 0 00 21 Spin medium 0 02 36 Pause 0 00 21 Rinse Fill Agitate warm or cold fast 0 02 39 Pause 0 00 21 Spin fast 0 08 39 0 29 21 OFF PAU...

Страница 9: ...23 4 75 d 132 25 d 24 5 00 d 137 25 d 25 4 75 d 142 00 d 26 5 75 d 147 75 d 27 5 75 d 153 50 d 28 4 75 d 158 25 d 29 7 50 d 165 75 d 3 0 7 50 d 173 25 d 31 7 50 d 180 75 d 32 7 50 d 188 25 d 3 3 4 75...

Страница 10: ...8 8 1 1 4 6 4 6 7 3 GRN YEL 5 7 3 5 WHT RED MIXING VALVE COLD GRN YEL HOT CABINET GROUND TO CORD POWER F A G K MED GROUND TO TOP BLK 18 GA WHT GRN VLT 11 5 14 BRN CONNECTOR BLU 10 16 PNK EX CB EXTRA...

Страница 11: ...1 TIMER BUSS INDICATES INTERNAL 120 VOLTS A C 60 HZ LID SWITCH N O EX A PS PRESSURE 11 A PS N EXTRA RINSE SW H O T MIXING VALVE C O L D 12 14 HI MED 2 SPEED MOTOR F L G L K TM MOTOR TIMER BP BP 2 1 K...

Отзывы: