Maytag sav2655aw Скачать руководство пользователя страница 5

Component Testing Information

 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless 
testing requires it. 
 

October 2003 

                               5 

16022616   Rev. 0

 

Illustration 

Component 

Test Procedure 

Results 

 
 

Extra Rinse Switch 
 

Disconnect wires from component to properly measure the 
resistance. Place switch in the following positions and 
measure across the terminals below. 
On YL-YL 
Off  

 
 
 
Continuity >1 

 

Infinite 

 

Temperature Switch 

Disconnect wires from component to properly measure the 
resistance. Place switch in the following positions and 
measure across the terminals below. 

 

 
 
 
 
 
 
 
>1 

 

>1 

 

>1 

 

>1 

 

 

 

 

 

 

 

POS

 

1

 

2

 

3

 

4

 

45°

 

90°

 

135°

 

INSERT

L2-2

L1-1&2, L2-2

L2-2

L1-1, L2-2

L1-1

SHAFT

CONNECTION

Содержание sav2655aw

Страница 1: ...l RS3100007 for detailed installation operating testing troubleshooting and disassembly instructions CAUTION All safety information must be followed as provided in this Technical Sheet and in Service...

Страница 2: ...h for continuity between terminals See component testing Check timer contacts Check for continuity on water valve solenoid See component testing Vibration Weak floors can cause vibration and walking L...

Страница 3: ...y need to be purged prior to starting wash cycle Disconnect inlet hoses and clean screens Will Not Spin Check for unbalanced load Does the house drain system accept water from machine Check for blocke...

Страница 4: ...old Side 2 25 gpm Hot Side 2 00 gpm Mix 3 00 gpm at 30 120 psi Measure resistance of terminals on each valve Resistance across each valve 1000 10 Drain Pump Verify Drain Pump is not clogged or damaged...

Страница 5: ...Rinse Switch Disconnect wires from component to properly measure the resistance Place switch in the following positions and measure across the terminals below On YL YL Off Continuity 1 Infinite Temper...

Страница 6: ...washer before servicing unless testing requires it 16022616 Rev 0 October 2003 6 4 POLE MAIN Y E L L O W 6 POLE MAIN BLUE VIOLET RED B R O W N AUX WHITE PROTECTOR WHITE Y BU BR W P R G RUN START WIRI...

Страница 7: ...n switch terminal P and Violet wire Manually depress actuator Continuity exists between switch terminal P and Violet wire Inoperative low speed switch Replace switch Motor switch checks OK NO YES YES...

Страница 8: ...Pause 0 00 21 Spin medium 0 02 42 Spin Spray warm or cold medium 0 00 21 Spin medium 0 02 36 Pause 0 00 21 Rinse Fill Agitate warm or cold fast 0 02 39 Pause 0 00 21 Spin fast 0 08 39 0 29 21 OFF PAU...

Страница 9: ...23 4 75 d 132 25 d 24 5 00 d 137 25 d 25 4 75 d 142 00 d 26 5 75 d 147 75 d 27 5 75 d 153 50 d 28 4 75 d 158 25 d 29 7 50 d 165 75 d 3 0 7 50 d 173 25 d 31 7 50 d 180 75 d 32 7 50 d 188 25 d 3 3 4 75...

Страница 10: ...8 8 1 1 4 6 4 6 7 3 GRN YEL 5 7 3 5 WHT RED MIXING VALVE COLD GRN YEL HOT CABINET GROUND TO CORD POWER F A G K MED GROUND TO TOP BLK 18 GA WHT GRN VLT 11 5 14 BRN CONNECTOR BLU 10 16 PNK EX CB EXTRA...

Страница 11: ...1 TIMER BUSS INDICATES INTERNAL 120 VOLTS A C 60 HZ LID SWITCH N O EX A PS PRESSURE 11 A PS N EXTRA RINSE SW H O T MIXING VALVE C O L D 12 14 HI MED 2 SPEED MOTOR F L G L K TM MOTOR TIMER BP BP 2 1 K...

Отзывы: