6

Electrical Requirements – Gas Dryer

IMPORTANT

: The dryer must be electrically grounded in

accordance with local codes and ordinances or, in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70,
latest edition.

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit
is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this dryer be provided.

Recommended Ground Method

The dryer, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, latest edition.

Electrical Requirements – Electric Dryer

(U.S. Only)

IMPORTANT

: The dryer must be electrically grounded in

accordance with local codes and ordinances or, in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70,
latest edition.

The National Electrical Code requires a 4-wire supply connection
for homes built after 1996, dryer circuits involved in remodeling
after 1996, and all mobile home installations.

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine
that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

A four-wire or three-wire, single-phase, 120/240 volt, 60 Hz,
AC only electrical supply (or four-wire or three-wire,
120/208 volt, if specified on the model/serial rating plate) is
required on a separate, 30-amp circuit, fused on both sides of
the line. A time-delay fuse or circuit breaker is recommended.

Recommended Ground Method

It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformity with the National Electrical Code, ANSI/NFPA 70,
latest edition, and all local codes and ordinances.

GROUNDING INSTRUCTIONS

SAVE THESE  INSTRUCTIONS

For a grounded, cord-connected dryer: 

This dryer must be grounded. In the event of a malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must be 
plugged into an appropriate outlet that is properly installed 
and grounded in accordance with all local codes and 
ordinances.

WARNING:

 

Improper connection of the equipment-

grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative or 
personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with the 
dryer: if it will not fit the outlet, have a proper outlet installed 
by a qualified electrician.

GROUNDING INSTRUCTIONS

SAVE THESE  INSTRUCTIONS

For a grounded, cord-connected dryer: 

This dryer must be grounded. In the event of a malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer uses a cord having an equipment-grounding 
conductor and a grounding plug. The plug must be plugged 
into an appropriate outlet that is properly installed and 
grounded in accordance with all local codes and ordinances.

For a permanently connected dryer:

This dryer must be connected to a grounded metal, 
permanent wiring system, or an equipment-grounding 
conductor must be run with the circuit conductors and 
connected to the equipment-grounding terminal or lead on 
the dryer.

WARNING:

 

Improper connection of the equipment-

grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or 
personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug on the power 
supply cord: if it will not fit the outlet, have a proper outlet 
installed by a qualified electrician.

Содержание MLE24PRAY

Страница 1: ...t may or may not contain doors with windows depending on model W10135153B W10135158A SP INSTRUCTIONS POUR L INSTALLATION D UNE S CHEUSE COMMERCIALE SUPERPOS E gaz 120 Volts 60 Hz ou lectrique 120 240...

Страница 2: ...the owner post in a prominent location instructions for the customer s use in the event the customer smells gas This information should be obtained from your gas supplier Post the following warning in...

Страница 3: ...he fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Clear the room building or area of all occupants In the State of Massachusetts...

Страница 4: ...ls and Parts Gather the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here Tools needed 8 or 10 pipe wrench 8 or 10 adjustable w...

Страница 5: ...cm 0 0 cm Back Sides Top Front Recessed 2 in 0 in 12 in 5 cm 0 cm 30 cm Back View 29 1 4 74 3 cm approx 1 2 5 cm 23 3 4 60 3 cm door top dryer exhaust bottom dryer exhaust 41 104 1 cm 76 3 4 195 cm 1...

Страница 6: ...rical installer to ensure that the electrical installation is adequate and in conformity with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances GROUNDING INST...

Страница 7: ...d on the model serial plate Burner input adjustments are not required when the dryer is operated up to this elevation When installed above 10 000 feet 3048 m a four percent 4 reduction of the burner B...

Страница 8: ...se an exhaust hood with a magnetic latch Do not install flexible metal vent in enclosed walls ceilings or floors 4 10 2 cm heavy metal vent and clamps must be used Use clamps to seal all joints Vent m...

Страница 9: ...amper Kits Part No 3391910 are available from your dealer or distributor and should be installed in the vent of each dryer to prevent exhausted air from returning into the dryers and to keep the exhau...

Страница 10: ...dryer is level 2 Using a Torx T20 security driver open the control panel and rest it on the bottom edge of the opening 3 For added security between the upper dryer and the collar insert the cotter ha...

Страница 11: ...cover into slot of the dryer rear panel Secure cover with hold down screw Four wire power supply cord must have four No 10 copper wires and match a four wire receptacle of NEMA Type 14 30R The fourth...

Страница 12: ...er terminal block screws Tighten screws 8 Tighten strain relief screws 9 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw D A C B 5 Remove the...

Страница 13: ...ning wires Strip insulation back 1 2 5 cm Shape ends of wires into a hook C B A E D F 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground condu...

Страница 14: ...erminal block cover into slot of the dryer rear panel Secure cover with hold down screw 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground con...

Страница 15: ...e dryer and allow it to complete a full heat cycle to make sure it is working properly ELECTRONIC CONTROL SETUP See Tech Sheet for information on setup Maintenance instructions Clean lint screen after...

Страница 16: ...s to parts or systems resulting from unauthorized modifications made to the commercial appliance 7 The removal and reinstallation of your commercial appliance if it is installed in an inaccessible loc...

Страница 17: ...flammables proximit de cet appareil ou de tout autre appareil lectrom nager On recommande que le propri taire place les instructions l usage du client un endroit bien visible pour le cas o le client p...

Страница 18: ...chage I Ne pas mettre la main dans la s cheuse si le tambour est en mouvement I Ne pas r parer ni remplacer une pi ce de la s cheuse ou essayer d en faire l entretien moins d une recommandation sp ci...

Страница 19: ...tion dans un encastrement Cette s cheuse peut tre install e dans un encastrement Les distances de s paration minimales sont mentionn es l arri re de la s cheuse Le circuit d vacuation de la s cheuse d...

Страница 20: ...vant Encastr 2 po 0 po 12 po 5 cm 0 cm 30 cm Dimensions du produit 29 1 4 po 74 3 cm approx 1 po 2 5 cm 23 3 4 po 60 3 cm Porte 76 3 4 po 195 cm Vue lat rale 27 po 68 6 cm 5 1 2 po 14 0 cm 10 1 2 po 2...

Страница 21: ...code en vigueur le permet on recommande qu un lectricien qualifi v rifie la qualit de la liaison la terre On peut obtenir un exemplaire du code national en vigueur l adresse suivante National Fire Pro...

Страница 22: ...t utilis e une altitude inf rieure cette valeur maximale Si la s cheuse doit tre utilis e une altitude sup rieure 10 000 pi 3048 m on doit r duire de 4 le d bit thermique du br leur indiqu sur la plaq...

Страница 23: ...du tuyau rigide n cessite une combinaison de raccords pour obtenir une connexion de la s cheuse en ligne Robinet d arr t n cessaire Conform ment aux prescriptions du National Fuel Gas Code ANSI Z223 1...

Страница 24: ...vacuation d pend du type de conduit utilis du nombre de coudes et du type de bouche de d charge La longueur maximale pour le circuit de conduit rigide est indiqu e dans le tableau ci apr s Pour un ci...

Страница 25: ...4 10 2 cm relier le conduit d vacuation la bouche d vacuation de la s cheuse Si on utilise le conduit d vacuation existant s assurer qu il est propre Le conduit d vacuation de la s cheuse doit tre fix...

Страница 26: ...e cordon d alimentation lectrique est branch R p ter le test de cinq minutes de fonctionnement 1 D connecter la source de courant lectrique M thode du cordon d alimentation U seulement Cette s cheuse...

Страница 27: ...ion du conducteur externe de liaison la terre Serrer la vis 8 Connecter le conducteur neutre blanc ou central du cordon d alimentation sous la vis de la borne centrale du bloc de connexion Serrer la v...

Страница 28: ...vis du serre c ble 9 Ins rer l onglet du couvercle du bloc de connexion dans la fente du panneau arri re de la s cheuse Immobiliser le couvercle avec la vis de retenue 5 ter la vis de la borne centra...

Страница 29: ...les instructions d installation qui suivent selon le type de raccordement Quatre conducteurs m thode recommand e Trois conducteurs si un circuit quatre conducteurs n est pas disponible M thode de c bl...

Страница 30: ...on la terre de l appareil de la vis de connexion du conducteur externe de liaison la terre Connecter le conducteur de liaison la terre et le conducteur neutre conducteur blanc ou central du c ble d al...

Страница 31: ...uation 1 l aide d une bride de fixation de 4 10 2 cm relier le conduit d vacuation la bouche d vacuation de la s cheuse Si on utilise le conduit d vacuation existant s assurer qu il est propre Le cond...

Страница 32: ...par sur place 6 Les r parations aux pi ces ou syst mes r sultant d une modification non autoris e faite l appareil commercial 7 La d pose et la r installation de votre appareil commercial si celui ci...

Отзывы: