![Maytag MLE24PDAYW Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/maytag/mle24pdayw/mle24pdayw_installation-instructions-manual_1748315014.webp)
14
14
A. 3/4" (19 mm) conduit connector
B. Neutral (white or center)
C. 10-gauge, 3 wire with ground
wire in flexible metallic conduit
A. External ground conductor screw
B. Center terminal block screw
C. Outer terminal block screws
D. Neutral (center wire)
E. Appliance neutral ground wire
Shape
ends of
wires into
a hook.
Strip 3
1
⁄
2
" (89 mm) of outer
covering from end of cable.
Strip insulation back 1"
(25 mm). If using 3 wire
cable with ground wire,
cut green or bare wire
even with outer covering.
Three wire with ground wire: green or bare
wire cut short. Wire is not used. Dryer is
grounded through neutral conductor.
To
disconnect
box
1” (25 mm)
of wires
stripped of
insulation
3
1
⁄
2
" (89 mm)
5.
Loosen or remove the center terminal
block screw.
6.
Place the hooked end of the neutral wire
(white or center) of the direct wire cable
under the center screw of the terminal
block (hook facing right). Squeeze
hooked end together. Tighten screw.
7.
Place the hooked ends of the other
direct wire cable wires under the outer
terminal block screws (hook facing right).
Squeeze hooked ends together. Tighten
screws.
8.
Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
5.
Remove the center terminal block screw.
6.
Remove the appliance neutral ground wire
from the external ground conductor screw.
Connect the appliance neutral ground wire
and the neutral wire (white or center) of the
direct wire cable under the center terminal
block screw. Tighten screw.
7.
Connect the other wires to outer terminal
block screws. Tighten screws.
8.
Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.
9.
After reattaching the terminal cover,
connect a separate copper ground wire
from the external ground connector screw
to an adequate ground.
If codes permit and a separate ground wire
is used, it is recommended that a qualified
electrician determine that the ground path
is adequate.
Direct Wire,
Three-wire electrical connection:
Use this method where local codes
permit connecting neutral ground wire to
neutral wire:
Use this method where local codes do
not permit connecting neutral ground
wire to neutral wire:
A
B
C
A
B
C
D
E
A. Separate copper ground wire
B. External ground conductor screw
C. Appliance neutral ground wire
D. Center terminal block screw
E. Outer terminal block screws
F. Neutral (center wire)
F
E
D
A
C
B