background image

7

Style 2: Direct wire strain relief

Remove the knockout as needed for the flexible conduit 
connection.

Assemble a UL listed conduit connector in the opening.

Tighten strain relief screw against the flexible conduit. 

4. Complete installation following instructions for your type of 

electrical connection:

4-wire (recommended)

3-wire (if 4-wire is not available)

Electrical Connection Options

4-wire connection: Power supply cord

Use this method for:

New branch-circuit installations (1996 NEC)

Mobile homes 

Recreational vehicles

In an area where local codes prohibit grounding through the 
neutral

1. Remove the ground-link screw from the range frame. Save 

the ground link screw and cup washer. Bend the ground-link 
away from the range so that it does not contact the range.

2. Connect the green ground wire from the power supply cord to 

the range using the ground-link screw and cup washer. The 
ground wire must be attached first and must not contact any 
other terminal.

3. Use a ¼" nut driver to remove the hex washer head screws 

from the terminal blocks. 

4. Connect the neutral (center) wire to the center terminal 

connector using one of the hex washer head screws. 
Securely tighten screw for proper electrical connection.

5. Connect the other 2 wires (lines 1 and 2) to the outer 

aluminum terminal blocks.

6. Securely tighten screws for proper electrical connection.

7. Tighten strain relief screws.

8. Replace terminal block cover.

A. Removable retaining nut
B. Strain relief

If your home has:

And you will be 
connecting to:

Go to Section:

4-wire receptacle
(NEMA type 14-50R)

A UL listed, 
250-volt 
minimum, 
40-amp, range 
power supply 
cord

4-wire connection: 
Power supply cord

4-wire direct

A circuit breaker 
box or fused 
disconnect

4-wire connection: 
Direct wire

3-wire receptacle
(NEMA type 10-50R)

A UL listed, 
250-volt 
minimum, 
40-amp, range 
power supply 
cord

3-wire connection: 
Power supply cord

3-wire direct

A circuit breaker 
box or fused 
disconnect

3-wire connection:
Direct wire

A

B

(12.7 cm)

5"

3"

(7.6 cm)

1"

(2.5 cm)

A. Ground-link  screw
B. Cup washer

C. Ground-link bent away from range

A. Line 1
B. Green ground wire

C. Ground-link screw
D. Hex washer head 

screw

E. Silver-colored terminal 

block screw

F. Ground-link

G. Neutral (center) wire 

H. Line 2

I. UL listed strain relief 

and 40- or 50-amp 
range power supply 
cord

A

C

B

A

B

C

D

E

F

G

H

I

Содержание MER7662WQ - Ceramic Range

Страница 1: ... potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can ki...

Страница 2: ...5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical Requirements section IMPORTANT To avoid damage to your cabinets check ...

Страница 3: ...codes Do not use an extension cord Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 WARNING Improper connection of the equipment groundi...

Страница 4: ...The ground must be revised so the green ground wire of the 4 wire power supply cord is connected to the cabinet See Electrical Connection Grounding through the neutral conductor is prohibited for new branch circuit installations 1996 NEC mobile homes and recreational vehicles or an area where local codes prohibit grounding through the neutral conductor When a 4 wire receptacle of NEMA Type 14 50R ...

Страница 5: ...unt anti tip bracket to wood floor drill two 3 2 mm holes at the positions marked on the bracket template Remove template from floor To mount anti tip bracket to concrete or ceramic floor use a 4 8 mm masonry drill bit to drill 2 holes at the positions marked on the bracket template Remove template from floor Tap plastic anchors into holes with a hammer 6 Align anti tip bracket holes with holes in...

Страница 6: ... remove cover from range 3 Add strain relief Style 1 Power supply cord strain relief Remove the knockout for the power supply cord Assemble a UL listed strain relief in the opening Tighten strain relief screw against the power supply cord WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instruct...

Страница 7: ...ct the neutral center wire to the center terminal connector using one of the hex washer head screws Securely tighten screw for proper electrical connection 5 Connect the other 2 wires lines 1 and 2 to the outer aluminum terminal blocks 6 Securely tighten screws for proper electrical connection 7 Tighten strain relief screws 8 Replace terminal block cover A Removable retaining nut B Strain relief I...

Страница 8: ...ehicles In an area where local codes prohibit grounding through the neutral 1 Remove the ground link screw from the range frame Save the ground link screw and cup washer Bend the ground link away from the range so that it does not contact the range 2 Connect the bare ground wire to the range using the ground link screw and cup washer The ground wire must be attached first and must not contact any ...

Страница 9: ...flashlight and look underneath the bottom of the range Look for the anti tip bracket securely attached to floor Slide range back so rear range foot is under anti tip bracket LevelRange 1 Place rack in oven 2 Place level on rack and check levelness of range first side to side then front to back 3 If range is not level pull range forward until rear leveling leg is removed from the anti tip bracket O...

Страница 10: ...ian MovingtheRange When moving range slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For power supply cord connected ranges 1 Slide range forward 2 Unplug the power supply cord 3 Complete cleaning or maintenance 4 Plug in power supply cord 5 Check that anti tip bracket is installed Look for the anti tip bra...

Страница 11: ...11 ANTI TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge ...

Страница 12: ...W10196158B 2008 All rights reserved 8 08 Printed in U S A ...