INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Tools needed

Parts supplied

Check that all parts are included. 

Anti-tip bracket must be securely mounted to subfloor. 
Thickness of flooring may require longer screws to anchor 
bracket to subfloor. Longer screws are available from your 
local hardware store.

Parts needed

If using a power supply cord kit:

A UL listed power supply cord kit marked for use with ranges. 
The cord should be rated at 250 volts minimum, 40 amps or 
50 amps that is marked for use with nominal 1

³⁄₈

" (3.5 cm) 

diameter connection opening and must end in ring terminals 
or open-end spade terminals with upturned ends.

A UL listed strain relief.

Check local codes. Check existing electrical supply. See 
“Electrical Requirements” section.

It is recommended that all electrical connections be made by a 
licensed, qualified electrical installer.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.  

It is the installer’s responsibility to comply with installation 
clearances specified on the model/serial rating plate. The 
model/serial rating plate is located on the left side frame 
behind the storage drawer panel.

The range should be located for convenient use in the 
kitchen.

To eliminate the risk of burns or fire by reaching over heated 
surface units, cabinet storage space located above the 
surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a range hood 
that projects horizontally a minimum of 5" (12.7 cm) beyond 
the bottom of the cabinets.

Cabinet opening dimensions that are shown must be used. 
Given dimensions are minimum clearances.

The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see “Install Anti-Tip 
Bracket” section.

Grounded electrical supply is required. See “Electrical 
Requirements” section.

IMPORTANT: To avoid damage to your cabinets, check with your 
builder or cabinet supplier to make sure that the materials used 
will not discolor, delaminate or sustain other damage. This oven 
has been designed in accordance with the requirements of UL 
and CSA International and complies with the maximum allowable 
wood cabinet temperatures of 194° (90°C).

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured 
Home Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction 
and Safety, Title 24, HUD Part 280). When such standard is not 
applicable, use the Standard for Manufactured Home 
Installations, ANSI A225.1/NFPA 501A or local codes.

Mobile home installations require:

When this range is installed in a mobile home, it must be 
secured to the floor during transit. Any method of securing 
the range is adequate as long as it conforms to the standards 
listed above.

Four-wire power supply cord or cable must be used in a 
mobile home installation. The appliance wiring will need to be 
revised. See “Electrical Connection” section.

Tape measure

Flat-blade screwdriver

Level

Hammer

Hand or electric drill

Wrench or pliers

Marker or pencil

Masking tape

¼" drive ratchet

¼" nut driver 

³⁄₈

" and 

⁵⁄₁₆

" nut driver

¹⁄₈

" (3.2 mm) drill bit (for 

wood floors)

³⁄₁₆

" (4.8 mm) carbide-tipped 

masonry drill bit (for 
concrete/ceramic floors)

A. Anti-tip bracket
B. Plastic anchors (2)

C. #10 x 1

¹⁄₂

" screws (2)

A

B

C

Содержание MER7662WQ - Ceramic Range

Страница 1: ... potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can ki...

Страница 2: ...5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical Requirements section IMPORTANT To avoid damage to your cabinets check ...

Страница 3: ...codes Do not use an extension cord Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 WARNING Improper connection of the equipment groundi...

Страница 4: ...The ground must be revised so the green ground wire of the 4 wire power supply cord is connected to the cabinet See Electrical Connection Grounding through the neutral conductor is prohibited for new branch circuit installations 1996 NEC mobile homes and recreational vehicles or an area where local codes prohibit grounding through the neutral conductor When a 4 wire receptacle of NEMA Type 14 50R ...

Страница 5: ...unt anti tip bracket to wood floor drill two 3 2 mm holes at the positions marked on the bracket template Remove template from floor To mount anti tip bracket to concrete or ceramic floor use a 4 8 mm masonry drill bit to drill 2 holes at the positions marked on the bracket template Remove template from floor Tap plastic anchors into holes with a hammer 6 Align anti tip bracket holes with holes in...

Страница 6: ... remove cover from range 3 Add strain relief Style 1 Power supply cord strain relief Remove the knockout for the power supply cord Assemble a UL listed strain relief in the opening Tighten strain relief screw against the power supply cord WARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instruct...

Страница 7: ...ct the neutral center wire to the center terminal connector using one of the hex washer head screws Securely tighten screw for proper electrical connection 5 Connect the other 2 wires lines 1 and 2 to the outer aluminum terminal blocks 6 Securely tighten screws for proper electrical connection 7 Tighten strain relief screws 8 Replace terminal block cover A Removable retaining nut B Strain relief I...

Страница 8: ...ehicles In an area where local codes prohibit grounding through the neutral 1 Remove the ground link screw from the range frame Save the ground link screw and cup washer Bend the ground link away from the range so that it does not contact the range 2 Connect the bare ground wire to the range using the ground link screw and cup washer The ground wire must be attached first and must not contact any ...

Страница 9: ...flashlight and look underneath the bottom of the range Look for the anti tip bracket securely attached to floor Slide range back so rear range foot is under anti tip bracket LevelRange 1 Place rack in oven 2 Place level on rack and check levelness of range first side to side then front to back 3 If range is not level pull range forward until rear leveling leg is removed from the anti tip bracket O...

Страница 10: ...ian MovingtheRange When moving range slide range onto cardboard or hardboard to avoid damaging the floor covering If removing the range is necessary for cleaning or maintenance For power supply cord connected ranges 1 Slide range forward 2 Unplug the power supply cord 3 Complete cleaning or maintenance 4 Plug in power supply cord 5 Check that anti tip bracket is installed Look for the anti tip bra...

Страница 11: ...11 ANTI TIP BRACKET TEMPLATE Cut on dotted lines and place the left edge against the left side cabinet and the top edge against the rear wall Left edge Top edge ...

Страница 12: ...W10196158B 2008 All rights reserved 8 08 Printed in U S A ...

Отзывы: