background image

112204 - 2

Maytag Co.

7

Installation Procedures _______________

Before installing the dryer, ensure the location conforms to
local codes and ordinances.  In the absence of such codes
or  ordinances  the  location  must  conform  with  the  National
Fuel  Gas  Code  ANSI.Z223.1  LATEST  EDITION,  or  in
Canada,  the  installation  must  conform  to  applicable
Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas)
or  CAN/CGA-B149.2-M91  (L.P.  Gas)  or  LATEST  EDITION
(for  General  Installation  and  Gas  Plumbing).

The operation of this dryer may affect the operation of other
types of gas dryers, which take their air for safe combustion
from  the  same  room.    If  in  doubt,  consult  the  dryer
manufacturer(s).

The dryer must be installed on a sound level floor capable
of supporting its weight.  Carpeting must be removed from
the floor area that the dryer is to rest on.

Provisions for adequate air supply must be provided as noted
in  this  manual  (refer  to  Fresh  Air  Supply  Requirements
section).

Clearance  provisions  must  be  made  from  combustible
construction as noted in this manual (refer to Dryer Enclosure
Requirements  section).

Provisions  must  be  made  for  adequate  clearances  for
servicing and for operation as noted in this manual (refer to
Dryer Enclosure Requirements section).

The  dryer  must  be  installed  with  a  proper  exhaust  duct
connection  to  the  outside  as  noted  in  this  manual  (refer  to
Exhaust Requirements  section).

The dryer must be located in an area where correct exhaust
venting  can  be  achieved  as  noted  in  this  manual  (refer  to
Exhaust Requirements  section).

IMPORTANT:

 The dryer should be located where a

minimal amount of exhaust ducting will be necessary.

The dryer must be installed with adequate clearance for air
openings into the combustion chamber.

IMPORTANT:

 The dryer must be installed in a location/

environment, where the ambient temperature remains
between 40° F (4.44° C) and 130° F (54.44° C).

Excessive Weight Hazard

Use two or more people and mechanical
equipment to lift, move and install dryer.

Failure to do so can result in back or other injury.

Explosion  Hazard

Keep flammable materials and vapors, such as
gasoline, away from dryer.

Do not install in a garage.

Failure to do so can result in death, explosion, or
fire.

Location Requirements _______________

Installation should be performed by competent professional
in  accordance  with  local,  state,  and  country  codes.    In  the
absence  of  these  codes,  the  installation  must  conform  to
applicable  American  National  Standards:  ANSI  Z223.1-
LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA
NO.  70-LATEST  EDITION  (National  Electrical  Code)  or  in
Canada,  the  installation  must  conform  to  applicable
Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas)
or  CAN/CGA-B149.2-M91  (L.P.  Gas)  or  LATEST  EDITION
(for  General  Installation  and  Gas  Plumbing)  or  Canadian
Electrical  Codes  Parts  1  &  2  CSA  C22.1-1990  or  LATEST
EDITION  (for  Electrical  Connections).

Leveling Dryer

The dryer is equipped with 4 leveling legs, 1 at each corner
of the base.  For optimum performance the dryer should be
level  front-to-back  and  side-to-side.

Tools Required

Utility Knife to remove packaging

9/16” Box wrench or 9/16” socket to remove pallet bolts

#2 Phillips screwdriver to open front toe panel

Pipe wrench for gas connections

7/8” open end wrench or adjustable wrench
to install coin box lock

TORX

®

 T20 TORX

®

 T25 to open rear bottom guard

to get foot adjustment ends

1/4” socket or 1/4” open end wrench to make the
leg adjustment

A pair of slip-joint pliers

®

TORX is a registered trademark of Textron Innovations, Inc.

Installing Door Handle

1. Remove handle from dryer tumbler.

2. Unwrap door handle from bubble wrap.

3. Locate handle standoff in the handle slots.

4. Insert 1/4-20 x 2-1/4” stainless Truss Head Phillips screws

through preexisting door holes.

5. Having  handle  flushed  against  door,  tighten  the  two

stainless Phillips screws.

!

 WARNING

!

 WARNING

Содержание MDG78PN

Страница 1: ...MDG78PN Installation Manual Part No 112204 2 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE...

Страница 2: ...Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas sup...

Страница 3: ...similarly textured rubber like materials Clean lint screen every third load to fourth Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint dust and d...

Страница 4: ...al disconnect device must be provided by the installer List of Acronyms _____________________ AWG American Wire Gauge HVAC Heating Ventilating and Air Conditioning in wc Inches of Water Column L C D L...

Страница 5: ...120 240V 1 2 3w 50 60 Hz APPROXIMATE NET WEIGHT 745 lb 337 93 kg APPROXIMATE SHIPPING WEIGHT 775 lb 351 53 kg AIRFLOW 60 Hz 600 cfm 17 00 cmm 50 Hz 500 cfm 14 16 cmm HEAT INPUT 60 Hz 130 000 Btu hr 3...

Страница 6: ...6 Maytag Co 112204 2 Specifications _____________________________________________________________________...

Страница 7: ...perature remains between 40 F 4 44 C and 130 F 54 44 C Excessive Weight Hazard Use two or more people and mechanical equipment to lift move and install dryer Failure to do so can result in back or oth...

Страница 8: ...Requirements _______ A The requirement to allow the door to open completely is 40 inches 101 6 cm B A minimum overhead clearance of 6 inches 15 24 cm is required C Dryer should be positioned a minimum...

Страница 9: ...ing must be 2 inches 5 08 cm larger than the duct all the way around The duct must be centered within this opening The ductwork for this dryer must be suitable for the appliance category in accordance...

Страница 10: ...own on the data label Electrical Service Specifications Multiple Dryer Common Venting IMPORTANT For extended ductwork runs the cross sectional area of the ductwork can only be increased to an extent W...

Страница 11: ...provided just in front of electrical box and insert 3 4 UL listed strain relief into the holes Single Phase 1 Wiring Connections Hookup The electrical input connections are made into the rear service...

Страница 12: ...dryer does not recommend the use of flexible gas supply line hose Pipe joint compounds that resist the action of natural propane and butane gases must be used on all non flare fittings In the U S A An...

Страница 13: ...ich will result in erratic operation of the burner ignition system Electric Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in...

Страница 14: ...ocal state and federal regulations or codes Installing the S A F E System The fire suppression system must be supplied with a minimum water pipe size of 1 2 inch 12 7 mm and be provided with 40 psi 20...

Страница 15: ...ocation installation conditions Turn on electric power to the dryer Refer to the operating instructions for starting your dryer Open all shutoff valves When a gas dryer is first started during initial...

Страница 16: ...unknown contact the Maytag Co for a distributor in your area NOTE When contacting the Maytag Co ensure to give the correct model number and serial number so that your inquiry is handled in an expediti...

Страница 17: ...________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ________...

Отзывы: