background image

4

Maytag Co.

112204 - 2

Specifications .......................................................... 5

Installation Procedures .......................................... 7

Location Requirements ........................................ 7

Dryer Enclosure Requirements ............................ 8

Fresh Air Supply Requirements ........................... 8

Exhaust Requirements ......................................... 8

Electrical Information ......................................... 10

Gas Information .................................................. 11

Water Information .............................................. 14

Preparation for Operation/Start-Up .................... 15

Preoperational Test ............................................ 15

Operating Instructions ........................................ 15

Shutdown Instructions ........................................ 16

Service/Parts Information ..................................... 16

Service ............................................................... 16

Parts ................................................................... 16

Routine Maintenance ............................................ 16

Cleaning ............................................................. 16

Data Label Information ......................................... 17

Important Information ________________

IMPORTANT:

 A means of restraint must be used to avoid

straining of the gas supply when the dryer is moved.

An external means of power removal (disconnect device)
must be provided by the installer.

List of Acronyms _____________________

AWG

American  Wire  Gauge

HVAC

Heating,  Ventilating,  and Air-Conditioning

in wc

Inches  of  Water Column

L.C.D.

Liquid  Crystal  Display

L.E.D.

Light  Emitting  Diode

L.P.

Liquid Propane

UL

Underwriters  Laboratory

“Caution:  Label  all  wires  prior  to
disconnection  when  servicing  controls.
Wiring  errors  can  cause  improper
operation.”

«Attention: Au moment de l’entretien des
commandes, étiquetez tous les fils avant
de  les  débrancher.    Des  erreurs  de
câblage 

peuvent 

entraîner 

un

fonctionnement inadéquat et dangereux.»

WARNING

The  dryer  must  never  be  operated  with
any of the back guards or service panels
removed.    Personal  injury  or  fire  could
result.

The wiring diagram for the dryer is located
behind the front control panel on the right
side.

Table of Contents ________

Содержание MDG78PN

Страница 1: ...MDG78PN Installation Manual Part No 112204 2 RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE...

Страница 2: ...Do not touch any electrical switch Do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas sup...

Страница 3: ...similarly textured rubber like materials Clean lint screen every third load to fourth Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint dust and d...

Страница 4: ...al disconnect device must be provided by the installer List of Acronyms _____________________ AWG American Wire Gauge HVAC Heating Ventilating and Air Conditioning in wc Inches of Water Column L C D L...

Страница 5: ...120 240V 1 2 3w 50 60 Hz APPROXIMATE NET WEIGHT 745 lb 337 93 kg APPROXIMATE SHIPPING WEIGHT 775 lb 351 53 kg AIRFLOW 60 Hz 600 cfm 17 00 cmm 50 Hz 500 cfm 14 16 cmm HEAT INPUT 60 Hz 130 000 Btu hr 3...

Страница 6: ...6 Maytag Co 112204 2 Specifications _____________________________________________________________________...

Страница 7: ...perature remains between 40 F 4 44 C and 130 F 54 44 C Excessive Weight Hazard Use two or more people and mechanical equipment to lift move and install dryer Failure to do so can result in back or oth...

Страница 8: ...Requirements _______ A The requirement to allow the door to open completely is 40 inches 101 6 cm B A minimum overhead clearance of 6 inches 15 24 cm is required C Dryer should be positioned a minimum...

Страница 9: ...ing must be 2 inches 5 08 cm larger than the duct all the way around The duct must be centered within this opening The ductwork for this dryer must be suitable for the appliance category in accordance...

Страница 10: ...own on the data label Electrical Service Specifications Multiple Dryer Common Venting IMPORTANT For extended ductwork runs the cross sectional area of the ductwork can only be increased to an extent W...

Страница 11: ...provided just in front of electrical box and insert 3 4 UL listed strain relief into the holes Single Phase 1 Wiring Connections Hookup The electrical input connections are made into the rear service...

Страница 12: ...dryer does not recommend the use of flexible gas supply line hose Pipe joint compounds that resist the action of natural propane and butane gases must be used on all non flare fittings In the U S A An...

Страница 13: ...ich will result in erratic operation of the burner ignition system Electric Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in...

Страница 14: ...ocal state and federal regulations or codes Installing the S A F E System The fire suppression system must be supplied with a minimum water pipe size of 1 2 inch 12 7 mm and be provided with 40 psi 20...

Страница 15: ...ocation installation conditions Turn on electric power to the dryer Refer to the operating instructions for starting your dryer Open all shutoff valves When a gas dryer is first started during initial...

Страница 16: ...unknown contact the Maytag Co for a distributor in your area NOTE When contacting the Maytag Co ensure to give the correct model number and serial number so that your inquiry is handled in an expediti...

Страница 17: ...________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ________...

Отзывы: