Electric Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electric
shock.
!
WARNING
11. Turn gas cock to “ON” position and check for leaks with
soap solution.
12. Reinstall the toe panel.
13. Reconnect the power.
Water Information ____________________
Before You Start
Check Local Codes and Permits
Call your local water company or the proper municipal
authority for information regarding local codes.
IMPORTANT:
It is your responsibility to have all plumbing
connections made by a qualified professional to ensure
that the plumbing installation is adequate and conforms to
local, state, and federal regulations or codes.
Installing the S.A.F.E. System
The fire suppression system must be supplied with a minimum
water pipe size of 1/2-inch (12.7 mm) and be provided with 40
psi +/- 20 psi (2.75 bar +/- 1.37 bar) of pressure.
If the rear area of the dryer or the water supply is located in
an area where it will be exposed to cold/freezing tempera-
tures, provisions must be made to protect these water lines
from freezing.
Connect the hose to the S.A.F.E. system. The dryer must be
connected to the cold water supply valve using a new flexible
supply line/coupling. Do not use old hoses.
1. Disconnect power from the dryer.
2. Remove rear panel.
3. Remove the 3/4” NH hose adapter from the tumbler.
4. Connect the 3/4” 11.5 NH hose adapter to the 3/8” N.P.T.
water connection located at the upper rear of the dryer.
5. Screw coupling on by hand until seated on the supply
valve.