11
STACKED WASHER/GAS DRYER INSTALLATION
REQUIREMENTS
Stacked Washer/Gas Dryer Electrical Requirements
IMPORTANT:
Observe all governing codes and ordinances.
NOTE:
In accordance with the European EMC Directive
(2014/30/EU), the maximum electricity supply system impedance to
which the gas dryer should be connected is declared to be
0.054 Ohm + j0.034 Ohm.
NOTE:
Electrical safety standards: The manufacturer has chosen
compliance with IEC/EN 60335 standards as the most appropriate
for this product.
This washer/dryer is supplied without an electric cord and plug. It
must be connected by a competent electrician to a single-phase
electricity supply at the voltage shown on the dataplate, using a
suitable fixed wiring installation in accordance with local and national
wiring regulations.
n
A 3-wire circular cord of minimum conductor size 1 mm
2
cross-
section area should be used.
n
A 10 A supply fuse should be used, and a switch having a
contact separation in both poles that provides full disconnection
under over-voltage category III conditions must be incorporated
into the fixed wiring in accordance with local wiring regulations.
The washer/dryer should be positioned so that the disconnection
switch is clearly visible and easily accessible to the user. This
disconnection switch also provides the function of an emergency
stop control for the user.
n
A cord clamp bush is provided on the washer/dryer, and
should be tightened on completion of wiring. The electrical
mains terminals are located behind the small rear access panel
(terminal block cover), and connections should be made in
accordance with the terminal markings. Remember to replace
the terminal access panel (terminal block cover).
If codes permit and an additional earth bond wire is used, it is
recommended that a qualified electrician determine that the earth
bond path is adequate.
Recommended Earthing Method
It is your responsibility to contact a qualified electrical installer to
ensure that the electrical installation is adequate and in conformance
with all local codes and ordinances.
This is 3-wire appliance which must be earthed.