Anti-Condensation Heating (Option)
The anti-condensation heating is used to prevent condensation
precipitate in the brake interior.
To connect the anti-condensation heating (AC voltage), see the
Wiring Diagram.
Condensation (Fig. 14)
The condensation must be checked regularly via the screw plug
(14) with the copper sealing ring (15).
Fig. 14
Disposal
Our electromagnetic brake components must be disposed of
separately as they consist of different materials. Please observe
the relevant authority regulations. Code numbers may vary
according to the disassembling process (metal, plastic and
cable).
Electronic Components
(Rectifier / ROBA-switch / Microswitch):
Products which have not been disassembled can be disposed of
under Code No. 160214 (mixed materials) or components under
Code No. 160216, or can be disposed of by a certified disposal
firm.
Brake bodies made of steel pads with coil / cable
and all other steel components:
Steel scrap
(Code No. 160117)
Aluminium components:
Non-ferrous metals (Code No. 160118)
Brake rotor (steel or aluminium pads with friction linings):
Brake linings
(Code No. 160112)
Seals, O-rings, V-seals, elastomers, terminal boxes (PVC):
Plastic
(Code No. 160119)
Malfunctions / Breakdowns:
Results of Malfunction
Possible Causes
Solutions
Brake does not release
Abraded particles between the armature disk and
the coil carrier.
Air gap too large
Air gap too small (remove the distance washers
before reaching the max. air gap)
Coil interruption
Rectifier failure
Incorrect voltage on rectifier
Clean the brake
Re-adjust the brake; replace the brake
Insert distance washers between the coil
carrier and the flange plate
Replace brake
Replace rectifier
Apply correct voltage
Brake does not brake
Emergency release screws are not loosened
Grease or oil on the friction surfaces
Loosen the emergency release screws
Replace rotor
Release monitoring
does not emit a signal
Abraded particles between the armature disk and
the coil carrier.
Switching position misaligned
Defective microswitch
Clean the brake
Adjust the switch again
Replace the switch
15
14
Condensate