 CLASSIFICATION

Classification:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Class II medical device.
Protection against electric shock: . . . . . . . . . . . . . . . . . . . . . . . . . . Internally powered equipment.
Protection against water:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IPX1
Mode of Operation:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous
Sterilization: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .See section 6.0
Flammable anesthetic mixture:. . . . . . . . . . . . . . . . . . . . . . . . Not suitable for use in presence of a  

flammable anesthetic mixture

        

Product Disposal Instructions:

      

The sensor, batteries, and circuit board are not suitable for regular trash  

      disposal. Return sensor to Maxtec for proper disposal or dispose    
      according to local guidelines. Follow local guidelines for disposal of 
      other components.

WARRANTY

Maxtec, warrants the Handi+ to be free from defects of workmanship or 
materials for a period of two-(2) years from the date of shipment from Maxtec, 
under normal operating conditions and provided that the Handi+ is properly 
operated and maintained in accordance with Maxtec's operating instructions.  
Should Handi+ fail prematurely, the replacement Handi+ is warranted for the 
remainder of the original analyzer warranty period. Based on Maxtec's product 
evaluation, Maxtec's sole obligation under the foregoing warranty is limited 
to making replacements, repairs or issuing credit for equipment found to be 
defective. This warranty extends only to the buyer purchasing the equipment 
directly from Maxtec or through Maxtec's designated distributors and/or 
agents as new equipment. Routine maintenance items are excluded from 
this warranty. Maxtec shall not be liable to the purchaser or other persons for 
incidental or consequential damages or equipment that has been subject to 
abuse, misuse, misapplication, alteration, negligence or accident. 

THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, 
EXPRESSED OR IMPLIED, INCLUDING WARRANTY OF MERCHANTABILITY AND FITNESS 
FOR A PARTICULAR PURPOSE.

     

EC REP

Содержание Handi+ R218P12

Страница 1: ...H Handi O P E R A T I N G M A N U A L I N S T R U C T I O N S F O R U S E R 2 1 8 P 1 2 R218M12 Rev J CAL...

Страница 2: ......

Страница 3: ...s from the date of shipment from Maxtec under normal operating conditions and provided that the Handi is properly operated and maintained in accordance with Maxtec s operating instructions Should Hand...

Страница 4: ...Improper use of this device can cause inaccurate oxygen readings which can lead to improper treatment hypoxia or hyperoxia Follow the procedures outlined in this user manual CAUTION Indicates a potent...

Страница 5: ...ation A 3 2 4 Direct Flow Calibration Configuration B 4 3 0 OPERATING THE HANDI 4 4 0 FACTORS INFLUENCING ACCURATE READINGS 5 4 1 Elevation Changes 5 4 2 Temperature Effects 5 4 3 Pressure Effect 5 4...

Страница 6: ......

Страница 7: ...blank The analyzer turns off after 1 3 minutes if no buttons are pressed Calibration Button Press the calibration CAL button to adjust the calibration value to reflect the known oxygen concentration T...

Страница 8: ...his oxygen analyzer ideal for portable oxygen analysis by qualified heath care professionals 2 0 CALIBRATING THE Handi 2 1 Before You Begin A protective film covering the threaded sensor face must be...

Страница 9: ...encing Calibration and Performance on page 5 of this manual Note We recommend use of medical grade USP or 99 purity oxygen when calibrating the Handi 2 3 In Line Calibration Configuration A 1 Put the...

Страница 10: ...ess the CAL button on the Handi The calibration gas value on the analyzer display should read 20 9 or 100 depending on the gas stream used 3 0 OPERATING THE HANDI To Check the Oxygen Concentration of...

Страница 11: ...e Handi will hold calibration and read correctly within 3 when in thermal equilibrium within the operating temperature range The device must be thermally stable when calibrated and allowed to thermall...

Страница 12: ...an error code occurs E03 No valid calibration data available Make sure unit has reached thermal equilibrium Press and hold the Calibration Button for three seconds to manually force a new calibration...

Страница 13: ...point on display located after the first digit Accuracy and Linearity 1 of full scale at constant temperature R H and pressure when calibrated at full scale Total Accuracy 3 actual oxygen level over...

Страница 14: ...on Dioxide 10 2 Helium 70 2 8 0 HANDI SPARE PARTS AND ACCESSORIES 8 1 Standard Replacement Parts and Accessories Part Number Item R218M12 Operation Manual Handi R218M12 001 Operation Manual Handi Inte...

Страница 15: ...calibration value Make sure that the calibration gas is connected to the Handi at 2 liters per minute for a minimum of 2 minutes prior to proceeding with calibration This 2 minute equilibration time...

Отзывы: