7
C. Li-Po, Li-Ion, Li-Mn Storage
No Battery
22.72V GV: 16mV
>
Type:LiPo 6S
22.72V GV: 16mV>
Type:
LiPo
6S
22.72V GV: 16mV>
Type:LiPo
6
S
CHG DHG
STO
BAL
CYCLE
START/ENTER
ESC/STOP
START/ENTER
ESC/STOP
START/ENTER
ESC/STOP
Storage Chg
LiPo 3S
0.7
A
START/ENTER
ESC/STOP
CC>22.79V 0.70A
>
20` 36mAH 0:03
CHG END 23.10V
>
20` 180mAH 0:15
Connect the Li** Battery Main wire Connector
& Balance Connector to X6-Plus
<3.78 3.79 3.78
3.80 3.78 3.79
INC
DEC
START/ENTER
<
3.79 3.80 3.80
3.81 3.79 3.80
INC
DEC
<
3.85 3.85 3.85
3.85 3.85 3.85
INC
DEC
Be. Be. Be
Press DEC & INC, Scroll through the setting within
LiFe, LiPo, LiIon,
LiMn.
Be Sure the charger is properly configured for the correct battery
type.
NO STOREGE MODE for LiFe battery
If you choose LiFe for
STO
mode, "
Bat Type Err
" will display
Press DEC & INC, Scroll through the setting of
cell numbers.
X6-Plus will set the cell numbers automatically according to the Balance
Connector connected.
Press DEC & INC, Scroll through the setting within
CHG, DHG, STO, BAL, CYCLE
Press DEC & INC, Scroll through the setting of
CHG/DHG Current.
0.1A/Step
X6-Plus will set the discharging current automatically according to the
battery pack's voltage & Max. discharge power.
If the battery cell voltage is lover than 3.85V, X6-Plus will charge it to
3.85V. Following FLOW is the same as CHG display
If the battery cell voltage is higher than 3.85V, X6-Plus will discharge it to
3.85V. Following FLOW is the same as DCH display
“Charging/Discharging END”screen:
the pack voltage, the pack
temperature, the capacity discharged and the time of
charging/discharging.
X6-Plus will stop charging/discharging when the cells voltage reach
3.85V
ESC/STOP
23.13V GV: 4mV
>
Type:LiPo 6S
<
3.85 3.85 3.86
3.85 3.86 3.85
INC
DEC
Because of the battery characteristic, after pressing“STOP", the voltage
will rise or drop a little according to the discharge or charge.