Li-Po, Li-Ion, Li-Mn, LiFePO4 Operation & Display
A. Li-Po, Li-Ion, Li-Mn, LiFePO4 Balance Charge
22.72V GV: 16mV>
Type:LiPo
6
S
CHG
DHG STO BAL
CYCLE
START/ENTER
ESC/STOP
START/ENTER
ESC/STOP
START/ENTER
ESC/STOP
LiPo
Normal
CHG
6S 2200mAH 2.2A
START/ENTER
ESC/STOP
LiPo Normal CHG
6S
2200
mAH 2.2A
START/ENTER
CC>23.37V 2.20A
>
20` 224mAH 0:05
CHG END 25.20V
>
20` 2198mAH 0:58
Connect the Li** Battery Main wire Connector
& Balance Connector to X6-Plus
No Battery
22.72V GV: 16mV
>
Type:LiPo 6S
<3.78 3.79 3.78
3.80 3.78 3.79
INC
DEC
ESC/STOP
LiPo Normal CHG
6S 2200mAH
2.2
A
START/ENTER
ESC/STOP
Starting charge
...............
START/ENTER
<
3.90 3.89 3.90
3.90 3.89 3.89
INC
DEC
<
4.20 4.20 4.20
4.20 4.20 4.20
INC
DEC
Be. Be. Be
22.72V GV: 16mV>
Type:
LiPo
6S
Press DEC & INC, Scroll through the setting within
LiFe, LiPo, LiIon, LiMn.
Be Sure the charger is properly configured for the correct battery type.
Press DEC & INC, Scroll through the setting of
cell numbers.
X6-Plus will set the cell numbers automatically according to the Balance
Connector connected.
Press DEC & INC, Scroll through the setting within
CHG, DHG, STO, BAL, CYCLE
•CHG: Charge mode
•DHG: Discharge mode
•STO: Storage mode
•BAL: Balance mode
•CYCLE: Discharge/Charge cycle mode
Press DEC & INC, Scroll through the setting of charging speed within
Slow, Normal, Fast.
Slow Normal Fast.
Charge current during CC 1C 1C 1C
Cut-off current during CV 1/30C 1/20C 1/10C
CHG END Balance accuracy <10mV <10mV
Press DEC & INC, Scroll through the setting of
Battery Capacity.
100mAH/Step
Be Sure the battery capacity is configured correctly according to the
battery pack.
Press DEC & INC, Scroll through the setting of
Charging Current.
0.1A/Step
X6-Plus will set the charging current=1C automatically according to the
battery pack capacity.
“Charging Status”screen:
the stage of the charge cycle (top left), the
pack voltage, the charging current, the pack temperature, the capacity
charged and the time of charging.
•ST: Initial charging of Li-xx battery
•CC: Constant current
•CV: Constant voltage
“Charging END”screen:
the pack voltage, the pack temperature, the capacity charged and the time of charging.
The X6-Plus will stop charging when the cells voltage reach the cut-off voltage(4.20V for Lipo & LiMn, 4.10V for LiIon,
3.60V for LiFe) or reach the capacity protection(120% of set battery capacity)
You can press “STOP” to stop charging anytime.