1.
On the bare wire end of Fused Power Cable, keep enough length to attach copper terminal
lug and reach Motor Solenoid without putting tension on cable (after connection)
(FIG. 15-
1A)
. Measure (if needed) and then cut excess cable from bare wire end of cable. Put
heatshrink tubing (Parts Box)
(FIG. 15-1B)
on the end of the cable (leave room for terminal
lug). Crimp copper terminal lug (from Parts Box) on the Fused Power Cable and shrink the
Heatshrink Tubing
(FIG. 15-1C)
.
STEP 5 - CONNECT POWER CABLE
TYPICAL FUSED POWER CABLE ROUTING
(POWER DOWN PUMP BOX SHOWN)
FIG. 15-1A
FIG. 15-1B
2.
Remove hex nut and lock washer from battery power post on the
RAISE
Motor Solenoid.
Connect the Fused Power Cable to the
RAISE
Motor Solenoid as shown in
FIG. 15-2
.
Re-install and tighten lock washer and hex nut.
COPPER TERMINAL LUG
FUSED
POWER CABLE
FUSED
POWER CABLE
BATTERY
POWER POST
LOCK
WASHER
HEX NUT
MOTOR SOLENOID
TYPICAL FUSED POWER CABLE ELECTRICAL CONNECTION
(POWER DOWN PUMP BOX SHOWN)
FIG. 15-2
HEATSHRINK TUBING
FIG. 15-1C
NOTE:
MAXON recommends using dielectric
grease on all electrical connections.