STEP 3 - WELD LIFTGATE TO VEHICLE - Continued
MEASURING DISTANCE ABOVE BED
LEVEL AT THE TIP OF FLIPOVER
FIG. 13-1
LEVEL LINE
TIP OF
FLIPOVER
1” MAX.
7.
At the tip of the Flipover, measure
distance Flipover is raised above bed
level. Tip
of Flipover should be above
level line shown in
FIG. 13-1
, and up to
1” maximum
(FIG. 13-1)
. If measure-
ment is correct, Liftgate is mounted
correctly. If measurement is incorrect,
check the measurements used for
preparing vehicle in
STEP 1
, and
if needed, repeat this entire step
(STEP 3)
.