![Maxon EPOS 50/5 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/maxon/epos-50-5/epos-50-5_hardware-reference-manual_1745151060.webp)
Setup
Status Indicators
EPOS4 50/5 Hardware Reference
3-60
CCMC | 2022-04 | rel10445
3.4.2
Device Status
The LEDs (
B
) display the actual status and possible errors of the EPOS4:
•
Green LED shows the status
•
Red LED indicates errors
Table 3-72
Device Status LEDs
3.4.3
NET Port
The LED (
C
) displays the link activity of the NET port (applies for both ports, X14 “IN” and
X15 “OUT”):
•
Green LED indicates link activity
Table 3-73
NET Port LED
LED
Description
Green
Red
Slow
OFF
Power stage is disabled. The EPOS4 is in status…
• “Switch ON Disabled”
• “Ready to Switch ON”
• “Switched ON”
ON
OFF
Power stage is enabled. The EPOS4 is in status…
• “Operation Enable”
• “Quick Stop Active”
OFF
ON
FAULT state. The EPOS4 is in status…
• “Fault”
ON
ON
Power stage is enabled. The EPOS4 is in temporary status…
• “Fault Reaction Active”
Flash
ON
No valid firmware or firmware download in progress
Flash = flashing (
≈
0.9 s OFF/
≈
0.1 s ON)
Slow = slow blinking (
≈
1 Hz)
LED
Description
Green
OFF
Port is closed
Flicker
Port is open / activity is present
ON
Port is open
—
Data rate is 100 Mbit/s
Flicker = continuous flickering (
≈
10 Hz)