![Maxon EPOS 50/5 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/maxon/epos-50-5/epos-50-5_hardware-reference-manual_1745151040.webp)
Setup
Connections
EPOS4 50/5 Hardware Reference
3-40
CCMC | 2022-04 | rel10445
Table 3-37
Digital input specification – Logic level setting
Figure 3-27
DigIN1 circuit (analogously valid for DigIN2…4) – Logic level setting
Table 3-38
Digital input specification – PLC level setting
Figure 3-28
DigIN1 circuit (analogously valid for DigIN2…4) – PLC level setting
Continued on next page.
Digital inputs 1…4 (Logic level setting)
Input voltage
0…30 VDC
Max. input voltage
±30 VDC
Logic 0
<0.8 V
Logic 1
>2.0 V
Input current at logic 1
250 µA @ 5 VDC
Switching delay
<300
μ
s @ 5 VDC
Digital inputs 1…4 (PLC level setting)
Input voltage
0…30 VDC
Max. input voltage
±30 VDC
Logic 0
<5.5 V
Logic 1
>9 V
Input current at logic 1
>2 mA @ 9 VDC
typically 3.5 mA @ 24 VDC
Switching delay
<300
μ
s @ 24 VDC