Sensor (X6)
Additional sensors, both incremental and serial encoders, can be connected.
Check on the applied sensor’s data sheet
If the specified inrush current or the maximum continuous current of the sensor should exceed 150 mA, you
can connect the sensor supply voltage (V
Sensor
) in parallel to the auxiliary output voltage (V
Aux
).
Figure 3-14
Sensor connector X6
Table 3-26
Sensor connector X6 – Pin assignment
Continued on next page.
X6
Head A
Prefab
Cable
Head B
Signal
Description
Pin
Color
Pin
1
white
1
Channel A
Digital/analog incremental encoder channel A
HsDigIN1
High-speed digital input 1
2
brown
2
Channel A\
Digital/analog incremental encoder channel A
complement
HsDigIN1\
High-speed digital input 1 complement
3
green
3
Channel B
Digital/analog incremental encoder channel B
HsDigIN2
High-speed digital input 2
4
yellow
4
Channel B\
Digital/analog incremental encoder channel B
complement
HsDigIN2\
High-speed digital input 2 complement
5
grey
5
Channel I
Digital/analog incremental encoder channel I
HsDigIN3
High-speed digital input 3
Clock
Clock (SSI)
HsDigOUT1
High-speed digital output 1
6
pink
6
Channel I\
Digital/analog incremental encoder channel I
complement
HsDigIN3\
High-speed digital input 3 complement
Clock\
Clock (SSI) complement
HsDigOUT1\
High-speed digital output 1 complement
7
blue
7
Data
Data (SSI)
HsDigIN4
High-speed digital input 4
8
red
8
Data\
Data (SSI) complement
HsDigIN4\
High-speed digital input 4 complement
9
black
9
GND
Ground
10
violet
10
V
Aux
Auxiliary output voltage (+5 VDC; I
L
≤
150 mA)