Setup
Connections
maxon motor control
ESCON Servo Controller
Document ID: rel4285
3-15
ESCON 50/5 Hardware Reference
Edition: September 2013
© 2013 maxon motor. Subject to change without prior notice.
3.3.3
Hall Sensor (J3)
Suitable Hall effect sensors IC use «Schmitt trigger» with open collector output.
Figure 3-4
Hall Sensor Plug J3
Table 3-11
Hall Sensor Plug J3 – Pin Assignment
Table 3-12
Hall Sensor Plug J3 – Specification & Accessories
Figure 3-5
Hall Sensor 1 Input Circuit (analogously valid also for Hall Sensors 2 & 3)
J3
Signal
Description
Pin
1
Hall sensor 1
Hall sensor 1 input
2
Hall sensor 2
Hall sensor 2 input
3
Hall sensor 3
Hall sensor 3 input
4
+5 VDC
Hall sensor supply voltage (+5 VDC; I
L
≤
30 mA)
5
GND
Ground
Specification / Accessories
Type
Pluggable screw-type terminal block, 5 poles, pitch 3.5 mm
Suitable cables
0.14…1.5 mm
2
multi-core, AWG 28-14
0.14…1.5 mm
2
single wire, AWG 28-14
Hall sensor supply voltage
+5 VDC
Max. Hall sensor supply current
30 mA
Input voltage
0…24 VDC
Max. input voltage
+24 VDC
Logic 0
typically <1.0 V
Logic 1
typically >2.4 V
Internal pull-up resistor
2.7 k
Ω
(a5.45 V – 0.6 V)