Motherboard (407582)
Attachments
maxon motor control
EPOS2 Positioning Controller
Document ID: rel8458
3-23
EPOS2 Module 36/2 MoBo Hardware Reference
Edition: November 2018
© 2018 maxon motor. Subject to change without prior notice.
3.2
Attachments
3.2.1
CAN Jumper (Link1)
Used for CAN bus termination on end modules. Bridges CAN L/H with built-in 120R resistor.
Figure 3-14
CAN Jumper (Link1)
3.2.2
Motor+ Link (Link2)
Used as Motor+ supply to J4 [Pin 1] by bridging the soldering pads.
Figure 3-15
Motor+ Link (Link2)
3.2.3
Motor- Link (Link3)
Used as Motor- supply to J4 [Pin 4] by bridging the soldering pads.
Figure 3-16
Motor- Link (Link3)
3.2.4
Fuse (Fuse1)
Figure 3-17
Fuse (Fuse1)
Rating for Replacement Fuse
Fast fuse 3 A; Littelfuse 3 A fast acting fuse
3.2.5
Fuse (Fuse2)
Figure 3-18
Fuse (Fuse2)
Rating for Replacement Fuse
Anti-surge fuse 2 A; Littelfuse 2 A anti-surge fuse