REV: 11/19/21

Package Contents:

1 - Round Flush-mount Housing

3 - Wirenuts (in parts bag)

1 - Round Flushmount Diffuser (shipped as part of flush mount housing)

1 - Installation Manual

2 - Electrical Box Screws (in parts bag)

1 - Mounting Plate (for 16”/ large only)

Any Changes expressly or modifications not approved by the party responsible for compliance could void the user’s authority to 

operate the equipment. 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may 

not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause 

undesired operation. 

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not 

occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of  the 

following measures: 

—Reorient or relocate the receiving antenna. 

—Increase the separation between the equipment and receiver. 

—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

—Consult the dealer or an experienced radio/TV technician for help. 

FCC Radiation Exposure Statement: 

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. 

This transmitter must not be co‐located or operating in conjunction with any other antenna or transmitter. 

This equipment should be installed and operated with minimum distance 20cm between the radiator & you body. 

CAN ICES-005(B)/NMB-005(B)

MaxLite

 

  

LED ARCHITECTURAL CCT SELECTABLE

®

 ML2LAxA Series

Содержание ML2LA A Series

Страница 1: ...PRODUCT DIMENSIONS General Safety Information To reduce the risk of death personal injury or property damage from fire electric shock falling parts cuts abrasions and other hazards read all warnings and instructions included with and on the fixture box and all fixture labels Before installing servicing or performing routine maintenance upon this equipment follow these general precautions Commercia...

Страница 2: ...e in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception whi...

Страница 3: ...CK BATTERY FHS2 UNV 36L LINE 120V BLACK COMMON WHITE GROUND GREEN Light Fixture Light Fixture LINE 120 277V BLACK COMMON WHITE DIM VIOLET DIM PINK GROUND GREEN Light Fixture Motion Sensor LINE 120 277V BLACK BLACK COMMON WHITE WHITE VIOLET DIM PINK DIM GROUND GREEN MMON WHITE LINE 120 277V BLACK WHITE BLACK WHITE WHITE TEST SWITCH RED RED BLACK BATTERY RED FHS2 UNV 36L BLACK LINE 120V BLACK COMMON...

Страница 4: ...Y BALLAST MUST BE GROUNDED TEST SWITCH RED BLACK BATTERY RED RED BLACK BLACK RED RED BLACK W WHITE C WHITE COMMON BLACK 120 277V WHITE BLACK LINE WHITE BLACK WHITE BLACK VIOLET DIM PINK DIM GROUND GREEN Light Fixture Motion Sensor LINE 120 277V BLACK BLACK COMMON WHITE WHITE VIOLET DIM PINK DIM GROUND GREEN COMMON WHITE LINE 120 277V BLACK WHITE BLACK WHITE WHITE WALL SWITCH TEST SWITCH RED RED BL...

Страница 5: ...el information Make all electrical and grounded connections in accordance with the National Electrical Code and any applicable local code requirements All wiring connections should be capped with UL approved wire connectors WARNING RISK OF INJURY RISK OF DAMAGE Luminaire may fall if inner bezel is not secured properly to outer bezel Ensure that the whole loop is positioned and secured under the wa...

Страница 6: ... is correct by comparing it with the luminaire label information Make all electrical and grounded connections in accordance with the National Electrical Code and any applicable local code requirements All wiring connections should be capped with UL approved wire connectors WARNING RISK OF INJURY RISK OF DAMAGE Luminaire may fall if inner bezel is not secured properly to outer bezel Ensure that the...

Страница 7: ... 5s III ON ON 5min IV ON 10min V ON ON 30min VI ON 60min VII 3 Stand by Period 1 2 3 4 5 6 I ON ON ON ON ON ON 2lux II ON ON ON ON ON 5lux III ON ON ON ON ON 15lux IV ON ON ON ON ON 25lux V ON ON ON ON ON 50lux VI ON ON ON ON ON 100lux VII ON ON ON ON ON Disable 4 Daylight Sensor 3 4 5 I ON ON ON 5s II ON ON 30s III ON ON 90s IV ON 3min V ON ON 20min VI 30min 2 Hold Time 1 2 I ON ON 50 II ON 35 II...

Страница 8: ...50 25 Ceiling mounted height 6m Sensitivity 100 75 50 25 Ceiling mounted height 9m Sensitivity 100 75 50 25 Ceiling mounted height 12m Sensitivity 100 75 50 25 Ceiling mounted height 15m Sensitivity 100 75 Normal moving Speed 1m s Normal moving Speed 1m s Normal moving Speed 1m s Normal moving Speed 1m s Normal moving Speed 1m s Slow moving Speed 0 3m s Slow moving Speed 0 3m s Slow moving Speed 0...

Страница 9: ... 9 Remote Control Initialization 1 On Off function 3 step dimming function After power on the sensor automatically turns on light at 100 brightness After 10sec it turns off the light During the initialization the sensor is not able to detect movement 2 2 step dimming function After power on the sensor automatically turns on light at 100 brightness After 10sec it dims the light to a low light level...

Страница 10: ...FORTH HEREIN IN NO EVENT WILL MAXLITE BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION DAMAGES RESULTING FROM LOSS OF USE PROFITS BUSINESS OR GOODWILL LABOR COSTS REMOVAL OR INSTALLATION COSTS DECREASE IN THE LIGHT OUTPUT OF THE LAMP AND OR DETERIORATION IN THE LAMP S PERFORMANCE WHETHER OR NOT MAXLITE HAS BEEN ADVISED OF THE POSSIBILITY THEREOF UNDER NO C...