Dip Setting
Operating Instructions
© Copyright 2021. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 973-244-7300 Fax: 973-244-7333 Email: [email protected]
Page: 7
REV: 11/19/21
1
2
I
ON
ON
100%
II
ON
-
75%
III
-
ON
50%
IV
-
-
10%
1) Detection Area
6
7
8
I
ON
ON
ON
0s
II
-
ON
ON
5s
III
ON
-
ON
5min
IV
-
-
ON
10min
V
ON
ON
-
30min
VI
-
ON
-
60min
VII
-
-
-
+
∞
3) Stand-by Period
1
2
3
4
5
6
I
ON
ON
ON
ON
ON
ON
2lux
II
-
ON
ON
ON
ON
ON
5lux
III
ON
-
ON
ON
ON
ON
15lux
IV
ON
ON
-
ON
ON
ON
25lux
V
ON
ON
ON
-
ON
ON
50lux
VI
ON
ON
ON
ON
-
ON
100lux
VII
ON
ON
ON
ON
ON
-
Disable
4) Daylight Sensor
3
4
5
I
ON
ON
ON
5s
II
-
ON
ON
30s
III
ON
-
ON
90s
IV
-
-
ON
3min
V
ON
ON
-
20min
VI
-
-
-
30min
2) Hold Time
1
2
I
ON
ON
50%
II
ON
-
35%
III
-
-
25%
5) Stand-by dim Level
MaxLite
LED ARCHITECTURAL CCT SELECTABLE
®
ML2LAxA Series