9
MAX Arm/Ultra Arm V1
Weld a horizontal bar across entire gate on any installation for strength.
DO NOT
weld the crossbar on just a few pickets, or they could bend.
Make sure that the operator is mounted level or it will not function properly. Arm should be mounted at least 12 inches above the ground.
Make sure there is slack in the operator cable.
DO NOT
over-bend the operator cable. Doing this will cause the wires to eventually break.
DO NOT
install on ANY pedestrian passageways, doorways, or gates.
gate safety installation
Horizontal Bar
Gate should have a smooth bottom edge, with vertical bottom edged protrusions not exceeding 0.50 inches.
If distance is greater than 4 inches for this area,
then entrapment protection is required.
If distance is less than 16 inches, entrapment protection is required in this area.
With the hinge mounted on the
corner of the pilaster, the
entrapment area is eliminated
and protection is NOT needed
for this area.
Gate Closed
Gate Opened
4” to 16”
DO NOT
install operator upside down.
DO NOT
install next to sprinklers or any area that may expose the system to water.
DO NOT
install on uphill or downhill gates.
Gate Closed
Gate Opened
Arm MUST be installed level.
MAX 10K mini sensing
edge works well in this
area if entrapment
protection is needed.
Hinge Area
Closed Gate
If the bottom of gate is 4 inches to 16” or higher above the
ground, then edge safety sensor must be installed.
Operator wire
should be in
flexible Conduit.