41
MAX Arm/Ultra Arm V1
EXIT PWR
ALARM
POWER /
SOLAR IN
BATTERY
INPUT
OPENING
CLOSING
MOTOR 2
MOTOR 1
ERD
OBD PORT
BLACK BOX
PROGRAMMING
SOLAR MODE
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MIN
MAX
OFF
MAX
SENSE
MAX
SENSE
BATTERY
BACKUP MODE
ERD SENSITIVITY
MOTION CONTROL
OPEN
CLOSING GATE SPEED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
STOP
CLOSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
BATTERY
TEST
BATTERY
INPUT
ERROR
BATTERY
IN USE
POWER
REPLACE
BATTERY
LEAVE
CLOSED
LEAVE
OPEN
OPEN
1 TIME
BATTERY VOLTAGE
E
F
1/2
RESET
ID
PLUG
MODULE
PORT
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
KEYPAD/CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE COM
COM
STOP
OPEN
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
ID PLUG
ERROR
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP
LOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE
OPEN
ON/OFF
BATTERY
CLOSE
DUAL
ON
ANTI-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
1
2
3
4
5
6
7
8
9
10
OFF
1
2
3
4
5
6
MIN
MIN
MAX
MAX
ON
OFF
2.5 sec
1.5 sec
FAULTS
OPERATOR
DSP ARM CONTROLLER
OFF
EXIT LOOP
16
MIN
16
MIN
3
1
14
12
9
7
3
1
14
12
9
7
UL SENSOR 10K
UL SENSOR N.C.
MODE A
MODE B
PROGRAM
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
MAXIMUM CONTROLS
DSP ARM CONTROLLER
obd port black box
test photo cls nc sensor
troubleshooting
These next pages can help troubleshoot problems that might occur after installation is complete.
Download a simple .txt file to troubleshoot gate operator errors and view event history.
Event type clarifica�on:
INFO: informa�onal message only
WARNING: unusual event but doesn't cause system malfunc�on
ERROR: abnormal event, could cause system malfunc�on
ENTRAP: entrapment detec�on event
Event Report:
Fri 07/11/2021 10:59:41
INFO : Cycle Counter
Fri 07/11/2021 10:59:41
ENTRAP : SEC_MC: First ERD Detected
Fri 07/11/2021 10:59:37
INFO : Radio Input Deac�vated
Fri 07/11/2021 10:59:36
INFO : Radio Input Ac�vated
Fri 07/11/2021 10:58:54
INFO : PRI_MC: Fully Open Posi�on Learned
Fri 07/11/2021 10:58:53
INFO : SEC_MC: Fully Open Posi�on Learned
Fri 07/11/2021 10:57:40
INFO : PRI_CIO: Communica�on Established
Fri 07/11/2021 10:57:38
ENTRAP : PRI_MC: Photo Cell Deac�vated
Fri 07/11/2021 10:57:34
ENTRAP : PRI_MC: Photo Cell Ac�vated
Fri 07/11/2021 10:57:21
INFO : Radio Input Deac�vated
Fri 07/11/2021 10:57:21
INFO : Radio Input Ac�vated
Fri 07/11/2021 10:56:46
WARNING: PRI_MC: Tamper Reported
Fri 07/11/2021 10:56:36
INFO : SEC_MC: Fully Open Posi�on Unknown
Fri 07/11/2021 10:56:36
INFO : PRI_MC: Fully Open Posi�on Unknown
Fri 07/11/2021 10:56:36
WARNING: PRI_MC: Tamper Reported
Fri 07/11/2021 10:56:33
ENTRAP : PRI_MC: Photo Cell Deac�vated
Fri 07/11/2021 10:56:33
ENTRAP : PRI_MC: Photo Cell Ac�vated
Fri 07/11/2021 10:56:33
ENTRAP : PRI_MC: Photo Cell Deac�vated
Fri 07/11/2021 10:56:33
ENTRAP : PRI_MC: Photo Cell Ac�vated
Event History Text Document Sample
o
bd
po
r
t
1. Plug MAX USB flash drive into OBD port. OBD LED will flash while file is downloading.
Remove flash drive after LED stops flashing (up to 5 minutes to download).
2. Plug flash drive into any computer USB port OR smart phone using a USB phone adapter.
The most recent 8000 events can be viewed. No special software required.
USB Phone
Adapter
Required
OR
Compute
r
Smar
t Phone
o
b
d
p
o
r
t
MAX
Flash Driv
e
Troubleshoot
PHOTO CLS NC
entrapment protection sensor (Photocell typically used):
1. Press and HOLD the STOP button & then the OPEN button together until beeping is heard, learn mode begins.
NOTE: DO NOT press the OPEN button before the STOP button or learn mode will NOT function.
3. Press STOP button again within 5 min. to end learn mode, beeping stops.
NOTE: If STOP button is not pressed within 5 min. learn mode automatically end after 5 min.
2. PHOTO CLS NC LED should be ON if an entrapment sensor is detected.
If
PHOTO CLS NC LED is NOT on, sensor has a problem.
Possible problems:
•
Photocells are out of alignment
•
Photocells are wired wrong - N.C. or N.O. depending on which
type of photocells are used
•
Sensor is bad
MOTION CONTROL
OPEN STOP
CLOSE
MOTION CONTROL
OPEN
STOP
CLOSE
Power
NC
Closing Direction
automatically monitored
OPEN ONLY
NC
OPEN ONLY
10K
PHOTO CLS
NC
OPEN/CLS
NC
GND
12VDC OUT
GND
CLS ONLY
10K
OPEN/CLS
10K
12VDC OUT
UL SENSOR N.C.
UL SENSOR 10K
P
NSOR N.C
P
NSOR N.C
P
SOR N.
P
SOR N
SOR N
SOR N
OR N
OR N
OR
UL SEN
UL SEN
UL SEN
UL SE
UL SE
UL SE
UL SE
UL S
L S
Содержание MAX ARM