50
MAX Arm/Ultra Arm V1.2
06-14-22
IMPORTANT:
Photocells MUST be powered by
12VDC OUT
or they will
NOT
be
MONITORED
.
12VDC OUT
Polarity does
NOT
matter
NC
C E
COM NO
RX
POWER
INPUT
EARTH
GND
SENSITIVITY
TX
POWER INPUT
TRANSMITTER
BOARD (TX)
ON
DIP
1
2
3
4
RECEIVER
BOARD (RX)
Sensitivity Adjustment:
If the photocell does not
respond to an obstruction,
lower the sensitivity by
turning adjustment
counter-clockwise.
Transmitter (TX)
Receiver (RX)
PHOTO CLS NC -
Normally Closed
GND -
Common
Green
LED
To
PHOTO CLS NC
and
12VDC OUT
Input
To Control Box
12VDC OUT
Input
Transmitter
(TX)
Receiver
(RX)
CLOSING direction Thru-Beam
Gate Closed
TX
RX
Green
LED
NOTE:
To meet the UL 325 2018 standard, Type B1
Non-Contact sensor entrapment protection device
MUST
be
MONITORED
by the gate operator.
Installation Steps:
1.
Set DIP-switches on receiver.
2.
Install jumper on receiver.
3.
Wire DSP
12VDC OUT
power to receiver.
4.
Wire
PHOTO CLS NC
to receiver photocell
NC.
Wire DSP Board
GND
to
receiver photocell
COM.
5.
Wire
12V
DSP
power to transmitter.
6.
Align photocells.
7.
Adjust sensitivity on receiver.
DIP-switches:
1, 2, 4 are
OFF.
Switch 3 is
ON
If trouble occurs, try
turning switch 4 OFF.
NOTE:
Power must be
cycled when switches
are changed.
IMPORTANT:
Photocells
MUST
be in alignment or fault will
occur. Green LED will remain
ON
receiver when in proper
alignment.
emx irb-mon
OPEN ONLY
NC
OPEN ONLY
10K
PHOTO CLS
NC
OPEN/CLS
NC
GND
12VDC OUT
GND
CLS ONLY
10K
OPEN/CLS
10K
12VDC OUT
UL SENSOR N.C.
UL SENSOR 10K
P
NSOR N.C
NSOR N.C
P
SOR N.
P
SOR N
P
SOR N
SOR N
OR N
OR N
OR
UL SEN
N
UL SEN
UL SEN
UL SEN
UL SE
UL SE
UL SE
L SE
L S
Photocell (Thru-Beam) CLOSING Direction
Single Gate Operator
Control Box
DSP Arm Controller
Blue Transmitter (TX) / Red Receiver (RX) Boards